76
Chapter 3
Setting the Mode
Selecting a Mode
Selecting a Mode
The
Mode
menu key is used to select the measurement personality you
have purchased with your instrument, or to select the basic or service
modes, which are native to the instrument. Upon turn-on the
instrument will default to the basic mode.
•
Mode
- Accesses the measurement personality mode. Press the key
that corresponds to the option mode you want to select, such as GSM
or cdmaOne. For a full explanation of the personality mode you
have purchased, see the documentation which comes with that
option.
• Basic - This mode is useful for making measurements that are not
preset to industry standards. They can be used for troubleshooting
your devices. Press
Mode
,
Basic
to switch to the basic mode, and
bring up the measurements menu. For more information on these
measurements go to
“Basic Measurements” on page 82
• Service These features will help you check the functionality of your
instrument. Press
Mode
,
Service
, to switch to the service mode, and
bring up the service measurements menu. Features accessed
through this menu include tests which check the timebase frequency,
the sensors on the RF board, and the functionality of the front panel
keys. For more information on these features go to
The basic waveform and spectrum measurements are available as
well as a power vs time measurement which is used only for
self-diagnostic purposes. The measurement setup parameters that
you select while in Service mode are only used for service mode. The
Basic mode settings are independent. Descriptions of the spectrum
and waveform measurements begin on
Note that spectrum and waveform measurements are available in each
personality mode, as well as in the basic and service modes. Each with
their own independent mode settings.
Press
Preset
to set the instrument to a known factory default state. This
sets the mode settings and all the measurements to the factory default
parameters.
Preset
does not switch the modes.
NOTE
Some features are intended for use only by service personnel and
cannot be accessed without a password. If after pressing a key, a
message appears requesting entry of a password, this means that the
feature is meant for service use only. The password is only available
through the service guide.
Summary of Contents for E4406A
Page 4: ...4 ...
Page 10: ...10 Contents ...
Page 138: ...138 Chapter4 Making Measurements Front Panel Test ...
Page 139: ...139 5 Functional Testing ...
Page 214: ...214 Chapter6 If You Have a Problem Returning Your Instrument to Agilent Technologies ...
Page 216: ...216 Chapter6 If You Have a Problem Repair Tag Goes Here Remove This Page ...
Page 217: ...217 7 Options and Accessories ...
Page 226: ...226 Chapter7 Options and Accessories Accessories ...