7-4
Messages
Sync Status
Sync Status
This field displays any errors that occurred while trying to synchronize the
demodulated data. Some screens use this field to display progress during multi-burst
measurement. When the measurement is completed to field returns to its normal
state.
Bad Sync (for
demodulation only)
This message appears if a synchronization error happened since the last
Demodulation Arm (when Adjust Mode is disabled) or since the last change to Trig
Delay (when Adjust Mode is enabled with Demod Arm already selected).
Possible causes of Bad Sync are:
•
Useful bits occurred while power was too low.
•
Demodulation trigger too early or too late.
•
FM (bit) errors found while synchronizing to desired midamble.
•
RF overload.
FM Error
At least one bit error was detected when comparing the measured midamble to the
selected Midamble or User Defined Sync Pattern, (Sync Mode=Midamble only).
Level Late
The amplitude of the burst did not rise until after the first few bits were received.
Level Short
The amplitude of the burst fell before the last few bits were received.
Low Level
The DSP analyzer’s RF level did not rise high enough to make a valid measurement.
No Error
No synchronization error occurred.
RF Ovrload
The measurement hardware overloaded during the measurement. (Increase RF
Analyzer Amplitude setting to correct).
ShortBurst
The amplitude envelope was shorter than the expected burst.
Summary of Contents for 8922M
Page 8: ...Contents Contents 6...
Page 21: ...1 1 1 Installing Your Agilent 8922M S...
Page 24: ...1 4 Installing Your Agilent 8922M S Fuses and Power Cords Power Cords Agilent Part Agilent...
Page 29: ...2 1 2 Making Measurements...
Page 59: ...2 31 Making Measurements If You Have Problems with a Measurement Figure 2 16...
Page 61: ...2 33 Making Measurements If You Have Problems with a Measurement Trigger Range For Pulsed RF...
Page 75: ...2 47 Making Measurements Advanced Features...
Page 76: ...3 1 3 Verifying Performance...
Page 106: ...3 31 Verifying Performance Agilent Technologies 8922M S Specifications...
Page 236: ...4 130 Screens Tests...
Page 237: ...5 1 5 Keys...
Page 238: ...5 2 Keys Key Map Key Map...
Page 276: ...6 28 Connectors Timing Diagrams Figure 6 3 Digital Demod Timing Diagram...
Page 277: ...6 29 Connectors Timing Diagrams Figure 6 4 Frequency Hop Timing Specification Table...
Page 278: ...6 30 Connectors Timing Diagrams Figure 6 5 RF Generator Hop Address Source Ext Timing Diagram...
Page 279: ...6 31 Connectors Timing Diagrams Figure 6 6 RF Analyzer Hop Address Source Ext Timing Diagram...
Page 280: ...6 32 Connectors Timing Diagrams Figure 6 7 RF Generator Hop Address Source Int Timing Diagram...
Page 281: ...6 33 Connectors Timing Diagrams Figure 6 8 RF Analyzer Hop Address Int Timing Diagram...
Page 282: ...6 34 Connectors Timing Diagrams Figure 6 9 Reset Hop Once Address Source Int Timing Diagram...
Page 284: ...6 36 Connectors Timing Diagrams Figure 6 11 Hop Inhibit Address Source Int Timing Diagram...
Page 297: ...8 1 8 Instrument BASIC...
Page 341: ...A 1 A APPENDIX A...
Page 364: ...A 24 APPENDIX A Protocol Log of a Typical Call...
Page 365: ...B 1 B Glossary...
Page 370: ...B 6 Glossary...