![Agilent Technologies 4352B Service Manual Download Page 280](http://html.mh-extra.com/html/agilent-technologies/4352b/4352b_service-manual_2867893280.webp)
Error
Messages
(Alphabetical
Order)
0282
Illegal
program
name
The
name
used
to
reference
a
program
was
invalid.
F
or
example
,
redening
an
existing
program,
deleting
a
nonexistent
program,
or
in
general,
referencing
a
nonexistent
program.
0283
Illegal
variable
name
An
attempt
was
made
to
reference
a
nonexistent
variable
in
a
program.
0213
Init
ignored
A
request
for
a
measurement
initiation
was
ignored
as
another
measurement
was
already
in
progress
.
159
INSUFFICIENT
memory
If
a
lot
of
tasks
are
executed
at
the
same
time
,
memory
might
be
insucient
for
a
while
.
(F
or
example
,
if
running
an
HP
Instrument
B
ASIC
program,
printing
a
screen,
and
sending
or
receiving
data
array
by
GPIB
are
requested
at
the
same
time
.)
W
ait
until
nishing
some
tasks
then
execute
the
next
task.
40
Insucient
RF
Level
The
input
level
to
the
4352B
RF
IN
connector
is
too
low
(less
than
020
dBm).
V
erify
that
the
DUT
is
correctly
connected
to
the
4352B .
Also
,
verify
that
the
power/control
voltage
output
is
turned
ON
on
the
LCD
display
information
(the
measurement
setting
parameter
display
or
the
status
notations).
If
it
is
OFF
,
press
4
DC
Pow
er
5
or
4
DC
Control
5 ,
and
press
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
OUTPUT
ON
off
.
This
message
is
also
displayed
if
a
positive
DC
voltage
component
(TTL
output,
etc
.)
is
included
in
the
DUT's
output
signal.
In
this
case
,
insert
a
high-pass
lter
to
suciently
eliminate
the
positive
DC
voltage
component.
0161
Invalid
block
data
A
block
data
element
was
expected,
but
was
invalid
for
some
reason
(see
IEEE
488.2,
7.7.6.2).
F
or
example
,
an
END
message
was
received
before
the
length
was
satised.
0141
Invalid
character
data
Either
the
character
data
element
contains
an
invalid
character
or
the
particular
element
received
is
not
valid
for
the
header
.
0121
Invalid
character
in
number
An
invalid
character
for
the
data
type
being
parsed
was
encountered.
F
or
example
,
an
alpha
character
in
a
decimal
numeric
or
a
\9"
in
octal
data.
0101
Invalid
character
A
syntax
element
contains
a
character
that
is
invalid
for
that
type
.
F
or
example
,
a
header
containing
an
ampersand
(SING& ).
171
INV
ALID
D
A
TE
The
date
entered
to
set
the
real
time
clock
is
invalid.
Re-enter
the
correct
date
.
Messages-7
Summary of Contents for 4352B
Page 11: ......
Page 31: ......
Page 73: ......
Page 80: ...Figure 3 4 List Box Menu Adjustments and Correction Constants 3 7 ...
Page 82: ...Figure 3 6 Reference Frequency Adjustment Location Adjustments and Correction Constants 3 9 ...
Page 85: ...Figure 3 9 Third IF AMP GAIN Adjustment Location 3 12 Adjustments and Correction Constants ...
Page 103: ...Figure 4 1 Troubleshooting Organization 4 2 Overall T roubleshooting ...
Page 113: ......
Page 130: ...Figure 5 11 Power Supply Block Diagram 1 Power Supply T roubleshooting 5 17 ...
Page 131: ...Figure 5 12 Power Supply Block Diagram 2 5 18 Power Supply T roubleshooting ...
Page 132: ...Figure 5 13 Power Supply Block Diagram 3 Power Supply T roubleshooting 5 19 ...
Page 133: ......
Page 135: ...Figure 6 1 Digital Control Group Simpli ed Block Diagram 6 2 Digital Control T roubleshooting ...
Page 146: ...Figure 7 2 Source Group Troubleshooting Flow Source Group T roubleshooting 7 3 ...
Page 154: ...Figure 8 2 Receiver Group Troubleshooting Flow Receiver Group T roubleshooting 8 3 ...
Page 198: ...Figure 10 1 Power Supply Functional Group Simpli ed Block Diagram Theory of Operation 10 3 ...
Page 203: ...Figure 10 3 Digital Control Group Simpli ed Block Diagram 10 8 Theory of Operation ...
Page 269: ......
Page 272: ...Figure B 1 Power Cable Supplied Power Requirement B 3 ...
Page 273: ......