HWS.1 Handy Wire Scanner - 240HW01V00
B2798_E 1.1, 2016-04-08
27
Signaling product inside the vertical measurement field (measurement possible):
Product centered in the vertical
measurement field, but not
centered horizontally: the box
is whole, but does not have
diameter values
Product centered in vertical
and horizontal measurement
field: The diameter reading is
viewed on the display
3. Horizontal inclination of the product
The display provides the indication regarding the horizontal inclination of the product if it is outside the foreseen
limits (± 7.5°). Misalignment is indicated by two arrows which appear next to the measurement box which request
rotating the instrument horizontally clockwise or anticlockwise.
The horizontal inclination between the instrument
and the product is greater than 7.5 °:
the arrows on the display request to rotate the instrument
horizontally
anticlockwise
The horizontal inclination between the instrument
and the product is higher than 7.5 °:
the arrows on the display request rotating the
instrument horizontally
clockwise
3.3
AVERAGING MODE
The averaging mode sets how the data is collected and how it is made the average to calculate the diameter
measurement. The choice depends on the required measurement speed, the type of product to be measured and the
required repeatability level.
To setup the Averaging Mode select
Setup (F1) → Measurement Setup→ Glass logic → On.
The setup procedure is described in the chapter on measurement setup
PLEASE REFER TO CHAPTER 2.14 MEASURE SETUP