Select the desired entry by using the 

arrow keys

 



 (

F2

 and 

F3

) and the 

Enter

 key (

F1

). 

To exit, restore factory calibration (resetting the offset) press 

Exit

 (

F4

) or select the entry 

Cancel 

and 

press 

Enter

 (

F1

). 

When the factory calibration is restored, the value displayed on the side of the entry Offset will be 
0.0000 and the icon 

 will no longer appear on the display 

 

 

 

Summary of Contents for HWS.1

Page 1: ...eroel it HWS 1 Handy Wire Scanner USER S MANUAL ENGLISH HW 240HW01V00 SW 600V00L02 B2798_E 1 1 VALIDAZIONE ANNULLAMENTO numero DTE B2798_E 1 0 foglio 1 di tot 36 Rif 240HW01V00 Redatto PS Ai sensi di...

Page 2: ......

Page 3: ...2 5 FIXTURE FOR THE ON LINE MEASUREMENT OPTIONAL 13 2 6 PULLEY SET FOR WIRE GUIDANCE WITH ADJUSTING WHEEL OPTIONAL DEVICE 14 2 7 FRONT PULLEY FOR WIRE GUIDANCE OPTIONAL DEVICE 16 2 8 CHARGING THE BATT...

Page 4: ...AEROEL s r l PRADAMANO UD ITALY 4 B2798_E 1 1 2016 04 08...

Page 5: ...component interface or parts in general sold but not manufactured by AEROEL e g Personal Computers Interfaces Printers and other peripherals etc will be covered by 12 months warranty starting from th...

Page 6: ...is advisable to use the following general precautions Work Area Safety Keep your work area clean and well lit Cluttered or dark areas invite accidents Do not operate equipment in explosive atmosphere...

Page 7: ...e accessories and protections described in the following chapters of this manual in any case avoid contact even accidentally with the product or moving parts Avoid measuring moving products if the typ...

Page 8: ...bjects The following uses are prohibited use of the HWS 1 portable micrometer in an environment other than air use of the HWS 1 portable micrometer in areas classified according to the directive 99 92...

Page 9: ...ce with the laws in force in matters of waste disposal without any additional cost to the Customer except for transport costs from the Customer s site to Aeroel s premises which will be at the Custome...

Page 10: ...d by 2 CCD sensors and allows the measurement of the diameter of the product The software YesWeGun for PC Windows is available in the CD ROM supplied with HWS 1 The program allows the management of HW...

Page 11: ...in parts Display Function keys Functio UBS Connector Upper optics Lower optics Handle Product being measured Safe Arm Trigger USB Connector Info and CE marking Fixing holes Display Function keys LED b...

Page 12: ...protection is also guaranteed by the holes in which the reference spheres are inserted see figure at right To unlock the protection just pull it out and remove it from the magnet blocks This protectio...

Page 13: ...o be fixed on the machine the holder contains a TAG that identifies the machine and which is read by the instrument at the time of measurement The support allows to easily and quickly place the scanne...

Page 14: ...wire guiding system is composed by 1 rail type ITEM 6 30x30 ITEM 0 0 419 01 Assembly of 2 ceramic pulleys and 1 pre setting wheel with 6 pre setting positions from 0 5 to 5 6 mm wire diameter The whe...

Page 15: ...sembly using the nuts sliding inside the rail groove Position the pulley assembly in order to apply a slight tension to the wire the pulley should rotate when the wire moves Now lock the assembly to t...

Page 16: ...he break of the instrument the dragging of the gun the expulsion and thrown of objects The front pulley are simply fixed to the instrument through the magnets that are located on the external faces of...

Page 17: ...along the charging cable In use when the battery charge power is low the device will automatically turn off after a warning message on the display 5 seconds 2 9 TURNING ON AND OFF To turn the instrum...

Page 18: ...3 and the Enter key F1 2 11 MAINTENANCE For the right maintenance you have to do when needed the cleaning of of the deflecting prisms This operation has to be done by using a clean cloth eventually da...

Page 19: ...e status 500 mA battery charger USB standard connected battery charge status PLEASE REFER TO CHAPTER 2 8 CHARGING THE BATTERY Dirty Optics Icon The icon is active when the instrument is used despite a...

Page 20: ...NING Labels of the function keys They indicate the menu or action that is obtained by pressing the respective function key from F1 to F4 In this case pressing F1 you enter the Setup menu of the instru...

Page 21: ...isplay shows the icon Glass Logic Option to be activated for the measurement of transparent product PLEASE REFER TO CHAPTER 3 4 GLASS LOGIC Selecting the item with the Enter key F1 you access the menu...

Page 22: ...y month year YYYY MM DD year month day Select the desired value using the arrow keys F2 and F3 and the Enter key F1 Time Change Selecting the item with the Enter key F1 you access the window for setti...

Page 23: ...ing options English Italiano Select the desired value using the arrow keys F2 and F3 and the Enter key F1 Calibration It is used to correct the calibration of the instrument setting a fixed offset val...

Page 24: ...g the averaging mode PLEASE REFER TO CHAPTER 3 3 AVERAGING MODE To press the trigger the Safe Arm must be in position A Attention The trigger is magnetically operated avoid operating in the presence o...

Page 25: ...fferent colors This horizontal bar moves vertically on the display in relation to the horizontal position of the product if the product moves outside the measurement field the bar moves upwards if the...

Page 26: ...e vertical centering status of the product by splitting the box in which the measurement value appears into two segments The display does not show whether this misalignment is above or below as can be...

Page 27: ...ing the instrument horizontally clockwise or anticlockwise The horizontal inclination between the instrument and the product is greater than 7 5 the arrows on the display request to rotate the instrum...

Page 28: ...ke a measurement comparable with laser measuring instruments installed in the production line performing average measurements not at a single point on the product 3 4 GLASS LOGIC By enabling the logic...

Page 29: ...ication tag optional 3 Press the trigger while the product enters the measurement field the instrument will emit a short beep 4 Keep the trigger pressed and position the product correctly in the measu...

Page 30: ...TO CHAPTER 2 5 FIXTURE FOR THE ON LINE MEASUREMENT OPTIONAL Attention to measure moving products PLEASE REFER TO CHAPTER 1 6 SPECIFIC SAFETY PROVISIONS Correctly mounting the support on the line allo...

Page 31: ...diameter of a master in the measurement field Selecting the entry opens a window where the diameter of the master in the measurement field is displayed sampling time 1 second with the resolution of 0...

Page 32: ...F2 and F3 and the Enter key F1 To exit restore factory calibration resetting the offset press Exit F4 or select the entry Cancel and press Enter F1 When the factory calibration is restored the value...

Page 33: ...HWS 1 Handy Wire Scanner 240HW01V00 B2798_E 1 1 2016 04 08 33 4 APPENDIX 4 1 FIXTURE DIMENSIONS...

Page 34: ...he equipment To do this follow these instructions Position the gun as shown and remove the adhesive metal plate HWS 1 Remove the 4 screws shown in the figure Loosen the screw shown in the figure and s...

Page 35: ...HWS 1 Handy Wire Scanner 240HW01V00 B2798_E 1 1 2016 04 08 35 For a possible repositioning of the shell you must perform the previous steps in reverse order Remove the battery out of its housing...

Page 36: ...AEROEL s r l PRADAMANO UD ITALY 36 B2798_E 1 1 2016 04 08...

Reviews: