3110 HELP FILES – SECTION 9
52
Figure 9.6 – The Network Tab in the Settings Window
To avoid having a new IP address dynamically
assigned, the 3110 can be assigned a static IP
that will remain fixed. Consult with your Network
Administrator for the IP Address, Netmask and set-
ting to be used.
Complete the following steps to assign a Static IP
Address for the 3110:
1. Select the Settings button and then open the
Network tab.
2. Select the IP Address check box and then
enter the IP address assigned by your Network
Administrator in the text box. Enter the Net-
mask information in the appropriate text boxes.
3. Press the “Save” button to save the new
information. A dialog message will state that
the 3110 must be rebooted to complete the IP
address assignment
4. Before rebooting the 3110, make sure all am-
plifiers connected to the system are disabled.
To quickly disable AE Techron amplifiers, press
the Stop button on the front panel of any ampli-
fier to place all connected units in Standby
mode. Consult the instructions for non-AE
Techron amplifiers to determine the best meth
-
od for disabling those units. After all amplifiers
have been disabled, the 3110 can be safely
rebooted by pushing the 3110’s front-panel
power switch to the OFF position and then
switching back to the ON position. To return all
AE Techron amplifiers to Run status, press the
Enable button on the same amplifier that was
used to place the amplifiers in Standby mode.
5. .Be sure to save any unsaved unsaved .swg
test files before rebooting the 3110.
Assign LAN Com Port
IMPORTANT:
Assigning a LAN Com Port to the
3110 or DSR System requires a reboot of the
3110. Before rebooting the 3110, make sure all
amplifiers connected to the system are disabled.
To quickly disable AE Techron amplifiers, press the
Stop button on the front panel of any amplifier to
place all connected units in Standby mode. Con-
sult the instructions for non-AE Techron amplifiers
to determine the best method for disabling those
units. After all amplifiers have been disabled, the
3110 can be safely rebooted by pushing the 3110’s
front-panel power switch to the OFF position and
then switching back to the ON position. To return
all AE Techron amplifiers to Run status, press the
Enable button on the same amplifier that was used
to place the amplifiers in Standby mode.
The LAN Com Port is used by the application layer
of networked equipment to establish host-to-host