Information subject to change
12-17-2018
3110 HELP FILES – SECTION 9
50
9.4.3 The Segment Defaults Tab
The
Segment Defaults
tab contains the default
settings for 3110 waveforms. When a new wave-
form is added into the main window, the initial
waveform properties will be determined by these
default settings. To change a default setting, select
the input box for that setting, and then type the
new setting into the text box or select the new
value from the dropdown window. Select Save
to save the new settings and close the Settings
window. To return all Segment Default settings to
the factory defaults, select the Reset to Defaults
button. See
Figure 9.4.
9.4.4 The System Calibration Tab
The
System Calibration
tab holds information
about the output generated by the DSR system or
the combined 3110/amplifier system. See
Figure
9.5.
Both system gain and system DC offset informa
-
tion are used by the 3110 to adjust its signal output
to produce the expected signal at the amplifier out
-
put. By default, a stand-alone 3110’s system gain
is set at 20 and the DC offset is set at 0. A DSR
system will have a gain setting determined by the
number of amplifiers contained in the system.
For accurate operation, the actual gain and offset
of your system should be tested by running the
Calibration Test. See the
“System Calibration”
Figure 9.4 – TheSegment Defaults Tab in the Settings Window