Electrical installation, cable connection, cable cover
Page 28 / 61
DLT-V6210 Manual V1.00
© by DLoG GmbH
NOTICE: Physical damage
Observe the potential ratios.
On DLT-V6210, logic ground and shield ground are firmly connected to each other.
Logic ground is the ground (GND) used to supply the internal parts and components such as the
display or CPU. All cable shields and the housing are connected to shield ground.
The chassis of some forklifts is on DC+. This means that DLT-V6210 chassis is also on DC+.
Short circuits can arise when, for example, the ground potential of a peripheral device is on DC-.
This may cause malfunctions or irreparable damage to DLT-V6210.
Always attach the ring tongue of the power supply cable to the provided ground bolt
situated on the connector panel.
The other end of the yellow-green power supply cable must be connected to the vehicle
chassis.
Connect the power supply cable of DLT-V6210 as directly as possible to the battery.
Don’t connect the power supply cable of DLT-V6210 to electromagnetically highly loaded
power supply lines (e.g. the engine power supply).
Don’t connect the power supply cable of DLT-V6210 to power supply lines which are
potentially loaded by other onsumers.
Connecting DLT-V6210 to large electrical loads, such as converters for the forklift motor
may result in random restarts, malfunctions and/or irreparable damage to the device.
If you want to connect devices fed by other power sources to DLT-V6210 (e.g. printers), be
sure to power up the peripheral devices at the same time or after DLT-V6210; otherwise,
you may encounter start-up problem, malfunctions or even irreparable damage to the
device.