Electrical installation, cable connection, cable cover
© by DLoG GmbH
DLT-V6210 Manual V1.00
Page 27 / 61
8.4.
Power cable, grounding
WARNING
Electrical shock or fire due to incorrect cable routing or insufficient grounding.
Only use original Advantech-DLoG power cables; they meet the specific requirements for
low-temperature flexibility, UV resistance, oil resistance, etc.
Make sure that the power supply cables are running without kinks and protected (securely
protected against crushing and abrading).
DLT-V6210 may only be connected to a SELV circuit (Safety Extra Low Voltage). The
SELV circuit is a secondary circuit that is designed to protect the voltage from exceeding
the safe value when operation runs correctly or a single error occurs.
The DC+ connecting cable must be protected by a fuse (30 AT max.).
The ignition connecting cable must be protected by a fuse of the following type:
5x20 mm T 125 mA L / 250 V, for example, a Wickmann 195-125 mA / 250 V.
Observe the correct voltage ranges.
Ensure that power supply cables are fused correctly.
Read the labeling on the cable and connect the power supply cable with the correct
polarity.
Cut the power supply cable to the minimum length to ensure the power supply with an
appropriate cable installation.
Connect the power supply cable to a suitable supply point.
Ensure that the connecting cable has an adequate cross section and ampacity at the
connection point.