Advanced Axis AX-CTL-1L Installation & Operation Manual Download Page 1

 

 

www.advancedco.com

Manual 

AX-CTL-1L, 2 and 4 

 
 

Intelligent Fire Alarm Control Panel 

 

 

 

Installation & Operation Manual

 

 
 
 
 
 
 

Summary of Contents for Axis AX-CTL-1L

Page 1: ...www advancedco com Manual AX CTL 1L 2 and 4 Intelligent Fire Alarm Control Panel Installation Operation Manual...

Page 2: ...s 17 4 2 1 3 SLC Peripheral Devices 18 4 2 1 3 1 Intelligent Smoke Detectors 18 4 2 1 3 1 1 Detector Bases 21 4 2 1 3 1 2 Isolator Base 4 for use with 55000 750ADV Isolator 25 4 2 1 3 1 3 6 Mounting B...

Page 3: ...E DACT 57 4 9 1 D9068P Serial Communications DACT Interfacing 57 4 9 1 1 Installing the AX SEB Serial Expansion Board and D9068P Bosch DACT 58 4 9 2 Relay Contact Interfacing to a Bosch D9068E DACT 60...

Page 4: ...ew Log 93 7 8 1 4 1 Event Log 93 7 8 1 4 2 Alarm Counter 93 7 8 1 5 View Panel 94 7 8 1 5 1 Local Hardware Viewing 94 7 8 1 5 2 Software Viewing 94 7 8 1 5 3 Network Hardware Viewing 94 7 8 2 Disable...

Page 5: ...1 Standby Batteries 111 10 2 2 Liquid Crystal Display 111 10 3 LED Status 112 10 3 1 AX CTL Base Card 112 10 3 2 AX LPD and AX NAC Module 113 10 3 3 AX NET4 AX NET7 Network Module 113 10 3 4 AV AMP 8...

Page 6: ...es in any combination of intelligent detectors and modules The AX CTL 1L AX CTL 2 and AX CTL 4 panels have resettable and non resettable power outputs each rated 0 5 Amp 24 VDC for connection to four...

Page 7: ...Interface Module Style 7 Class A 682 013 AX MOXA Fiber Optic Converter Module for AX NET4 or AX NET7 682 260 AX DCI 24 VDC Isolator Module for AX MOXA 682 260 AX RL8 Eight Relay Output Module 682 006...

Page 8: ...nalog Addressable Duct Smoke Detector ION 4 Wire AP 330 AX SL DA4R P Analog Addressable Duct Smoke Detector PHOTO 4 Wire AP 330 55000 750ADV Isolator Module requires 45681 211ADS Isolator Mounting Bas...

Page 9: ...ication Appliance with compatible ratings may be installed including previously installed devices in existing facilities Compatible Pre Action Deluge Releasing Solenoid Document 73218BN4UNLVNOC111C2 S...

Page 10: ...ain a written record of all inspections and maintenance performed 1 4 General Installation Notes WARNING Disconnect all sources of power AC and battery before installing components or servicing the sy...

Page 11: ...Emissions WARNING This equipment generates uses and can radiate radio frequency energy If it is not installed in accordance with the instructions in this manual it may cause interference to radio comm...

Page 12: ...de NEC State and Local codes 3 1 Enclosure Mounting and Dimensions The AX CTL 1L AX CTL 2 and AX CTL 4 enclosure may be either surface or semi flush mounted 14 5 369 16 0 405 22 6 575 24 1 612 6 3 160...

Page 13: ...graphic display in the double aperture location and two AX SAPs single aperture plates in the single aperture locations see figure 2 3 2 1 3 2 2 Inner Door Aperture Modules Below is a list of inner do...

Page 14: ...re alarm control panels Additional circuit cards modules for field expansion present and future are available and shipped in separate packing for protection Prior to mounting the enclosure remove all...

Page 15: ...t insulation rating 4 1 2 Replacing the AX ACB AC Board If replacing the AX ACB AC board remove power AC and battery from the system Remove all Molex connector plugs and the green ground wire plug fro...

Page 16: ...on the rear of the back box The AX CTL base card is hung on five top hat screw less standoffs and secured with three 3 screws p see figure 5 It is critical when replacing the base card that these scre...

Page 17: ...ected the charger output is turned off Internal series resistance of the batteries is continuously checked If the internal series resistance increases above 0 8 the panel will indicate a battery troub...

Page 18: ...2 25 1 4 16 64 2 8 32 26 1 4 16 64 2 8 32 27 1 4 16 64 2 8 32 28 1 4 16 64 2 8 32 29 1 4 16 64 2 8 32 30 1 4 16 64 2 8 32 31 1 4 16 64 2 8 32 32 1 4 16 64 2 8 32 33 1 4 16 64 2 8 32 34 1 4 16 64 2 8 3...

Page 19: ...or environments in which sources of unwanted alarms are rare i e clean rooms and computer rooms Response mode 5 set detectors would be suitable for more dusty or harsh environments i e boiler rooms lo...

Page 20: ...a minimum analog value the AX CTL 1L AX CTL 2 or AX CTL 4 AX CTL base card will enter a trouble fault warning i e Device Dirty condition for that specific device In addition a device trouble condition...

Page 21: ...ying CO test gas through its outer edge opening or by manually initiating a test command from the AxisAX fire alarm control panel The built in Sounder Base is capable of providing a temporal 3 sub add...

Page 22: ...advancedco com 22 4 2 1 3 1 1 1 1 Intelligent CO Detector and Sounder Base Wiring 4 2 1 3 1 1 2 E Z Fit Detector Base Wiring 6 L1 L2 R R Optional Remote LED From AxisAX SLC _ To Next AxisAX Periphera...

Page 23: ...www advancedco com 23 4 2 2 1 1 1 3 Relay Detector Base Wiring 4 4 2 1 3 1 1 4 Isolator Detector Base Wiring 4...

Page 24: ...www advancedco com 24 4 2 1 3 1 1 5 Loop Powered Sounder Beacon Base Wiring 6 4 2 1 3 1 1 6 Enhanced Loop Powered Sounder Beacon Base Wiring...

Page 25: ...www advancedco com 25 4 2 1 3 1 2 Isolator Base 4 for use with 55000 750ADV Isolator 4 2 1 3 1 3 6 Mounting Base Adapter Kit Mounting Plate Trim Ring O U T I N...

Page 26: ...ments of the Americans with Disabilities Act ADA Activation of the pull station meets the requirements for five pound maximum pull force and the single hand activation Each AX APS2 xx station is equip...

Page 27: ...des a key lock for resetting CAT B CAT 30 which is common with the AxisAX fire alarm control panel The 56000 005ADV stations are UL 38 Listed meet the ADAAG controls and operating guidelines and the A...

Page 28: ...6 32 64 1 2 3 4 5 6 7 O N 48 1 2 4 8 16 32 64 1 2 3 4 5 6 7 ON 49 1 2 4 8 16 3 2 64 1 2 3 4 5 6 7 ON 50 1 2 4 8 16 32 64 1 2 3 4 5 6 7 ON 51 1 2 4 8 1 6 32 64 1 2 3 4 5 6 7 ON 52 1 2 4 8 16 32 6 4 1...

Page 29: ...able of being wired Class A or B to the monitored contact device s An integral eight position programming DIP switch must be set for device addressing and wiring classification definition Each 55000 8...

Page 30: ...figure 10 Priority Switch Monitor Module 55000 806ADV The 55000 806ADV Priority Switch Monitor Module is identical to the 55000 805ADV Switch Monitor Module with the exception of a priority interrupt...

Page 31: ...lligent Input Output Modules I O Relay Output Switch Monitor Module 55000 820ADV The 55000 820ADV I O Relay Output Switch Monitor Module is an application specific addressable module for use with the...

Page 32: ...em point capacities are expanded with installation programming and commissioning time minimized The 55000 859ADV mounts to the front of a standard 4 square or 2 gang electrical outlet box Displayed on...

Page 33: ...ssigned to a common group address to be activated from a single command poll from the intelligent fire alarm control panel An eight position programming DIP switch is provided on each 55000 825ADV mod...

Page 34: ...AxisAX Dynamix I O Relationship Programming the Relay Module s Form C outputs can be assigned to any input or output relationship output group timing function gated function etc to enhance project sp...

Page 35: ...Maximum line impedance at 2 0A is 1 5 Maximum voltage drop across installation wiring is 3 0V at battery voltage of 20 4V Calculate the maximum line impedance and conductor size required for the actua...

Page 36: ...ming allows the notification appliance circuit to be active 24 VDC during a non alarm and off during alarm 4 2 1 5 AX CTL Relay Contacts The AX CTL provides three programmable Form C relay contacts Th...

Page 37: ...AX CTL USB Port The AX CTL provides a USB port for PC NeT upload download programming of the system 4 2 1 8 AX CTL RS 232 Port The AX CTL provides an RS 232 port for programming and connection of anci...

Page 38: ...s are not required Note The AX CTL 1PCB one loop base card cannot support the AX PSU AX LPD or AX NAC option modules Nominal 27 4 VDC temperature compensated to track main panel DC supply By adding an...

Page 39: ...Carefully slide the AX CTL up and off of the five top hat screw less standoffs see figure 17 Carefully slide the new AX CTL over the five top hat screw less standoffs and insert tighten the previously...

Page 40: ...CTL 2V or AX CTL 4V see figure 18 In addition the AX DSP has three 3 buttons and six 6 LEDs that can be customized to meet specific installation requirements Customized buttons and LEDs have easy slid...

Page 41: ...mal closed contacts depending upon installation need see figure 20 4 3 3 Replacing the AX DSP Alphanumeric Graphical Display If replacing the AX DSP alphanumeric graphical display remove power AC and...

Page 42: ...ort the AV MIC microphone assembly In addition when an AV AMP 80 audio amplifier module and AX PSU 6 power supply charger module are utilized the AxisAX Intelligent Fire Alarm Control Panel cannot sup...

Page 43: ...ng This trigger input has the highest priority if both trigger input 1 and 2 are active during a trigger input 3 activation amplifiers will broadcast the external audio input signal This is how live v...

Page 44: ...demands such as alarms alerts warnings mass notification and other event messaging requirements Messages can be automatically activated with programmable prioritization or manually activated based on...

Page 45: ...move from the mounting plate as this is part of the assembly and is required for heat sinking the AV AMP 80 If replacing the new AV AMP 80 will be supplied pre assembled to a mounting plate OUT OUT IN...

Page 46: ...ese screws be tightly secured as they are required for proper earth ground connection Reinstall all removed field wiring terminal blocks from the audio amplifier module and reconnect AC and battery po...

Page 47: ...ll the provided nylon spacer into the fourth mounting hole on the AV ZS module as indicated in figure 25 Mount the AV ZS audio zone splitter module above the AV AMP 80 audio amplifier module to the th...

Page 48: ...th a PBUS RS485 AV AMP 80 amplifier the All audio notification appliance circuit activation input is constantly activate thereby allowing for audio control via PBUS RS485 activation of the two 2 onboa...

Page 49: ...y charger place the module over the four 4 standoffs located on the right side of the back box below the AX CTL base card and secure with the four 4 screws provided with the AX PSU 6 module see figure...

Page 50: ...PSU 6 AC Wiring AC Branch Circuit Ratings 120V 240V 3A 50 60Hz Brown out 98V nominal 15A Branch Circuit Fuse 5A 250VAC Ceramic Time Delay size 5x20mm Advanced part number 620 003 Bussmann S505 5 R Lit...

Page 51: ...checked If the internal series resistance increases above 0 8 then the AX PSU 6 will indicate a trouble condition 4 6 2 3 AX PSU 6 24 VDC and Trouble Fault Contact Wiring The AX PSU 6 24 VDC power ou...

Page 52: ...ion appliance circuits The AX NAC is a NAC expansion module providing two 2 notification appliance circuits 4 7 1 Installing the AX LPD or AX NAC Module Note The AX CTL 1PCB one loop base card cannot...

Page 53: ...OUTPUTS OUT OUT IN IN LOOP 1 NC NO COM RELAY 1 NC NO COM RELAY 2 NC NO COM NETWORK A C MAINS ANC PSU ANC FAULT PSU P BUS BAT BAT START FROM BATTERY PROG RUN LOCK MEM MASTER PROGRAM RELAY 3 LOOP 2 NAC...

Page 54: ...screws securing the module to the AX CTL base card and remove the module Position the new module onto the metal hexagon spacers while plugging the module into the two 2 20 pin connectors on the AX CT...

Page 55: ...nstalling the AX NET4 or AX NET7 Module Note All AxisAX fire alarm control panels can support networking capabilities The AX NET4 and AX NET7 modules are supplied with one metal hexagon spacer screw a...

Page 56: ...ring Maximum cable length between nodes is 5000ft 1500m using recommended cables Maximum overall cable length is 66000ft 20000m using recommended cables 4 8 3 Replacing the AX NET4 or AX NET7 Module R...

Page 57: ...e alarm control panel s AX CTL base card an Advanced AX SEB serial expansion board is required The AX SEB serial expansion board plugs into the AX CTL base card serial expansion port and provides RS 2...

Page 58: ...tom left corner of the AX CTL base card see figure 26 The AX SEB comes with two ribbon cables one 6 pin and one 5 pin these cables are for connecting the AX SEB to the D9068P DACT Connect the 6 pin ri...

Page 59: ...9068P this connection allows the DACT PRG to be connected to the AX SEB board for D9068P programming see figure 32 The D9068P is mounted on the left sidewall of the enclosure back box On the upper lef...

Page 60: ...y contacts a D9068E DACT is required The D9068E comes in its own enclosure that can be mounted adjacent to the fire alarm control panel In addition the D9068E module can be removed from the enclosure...

Page 61: ...AX CTL 4 intelligent fire alarm control panel interfaced to a FireLite Model 411UDAC for Central Station connection see figure 35 Note Though the interface to a Model 411UDAC is shown the AX CTL 1L AX...

Page 62: ...B S1 A 1 0 1 2 3 4 1 2 4 8 NO 1 0 S2 TB2 TB3 TB1 SOUNDER PA Vext Vext 24 VDC In NonResettable Power 24 VDC Out NonResettable Power Set Jumper to Sounder J1 To Line Reversal Receiving Equipment If tro...

Page 63: ...utilized with the PBUS RS485 AV AMP 80 audio amplifier switches can be configured for all call selective zone area paging individual message selection etc LEDs can be programmed for a number of differ...

Page 64: ...r other fire alarm listed power supply Wire 24 VDC filter regulated power to terminals and of the switch LED module see figure 39 Refer to AxisAX Wiring Guide Section Error Reference source not found...

Page 65: ...e to the inner door Remove the switch LED module and replace with the new switch LED module between the aperture screws and secure with the removed nuts and washers Replace the unplugged terminal bloc...

Page 66: ...for the AX LPD or AX NAC module notification appliance circuits Note The AX CTL 1L cannot support the AX PSU expansion power supply 4 14 1 Adding or Replacing the AX PSU Module If adding an AX PSU mo...

Page 67: ...RL4 AV AMP 80 or AX CZM module is installed in the AxisAX enclosure an AX RL8 eight relay output module cannot be added 4 15 1 Adding or Replacing an AX RL8 Module If adding an AX RL8 module mount th...

Page 68: ...ogrammable Form C relay contacts for project specific control functions The AX RL4 is listed to switch DC or AC voltage and up to sixteen 16 AX RL4 modules can be connected to a single AX CTL base car...

Page 69: ...sAX fire alarm control panel By supporting sixteen 16 AX CZM modules an AxisAX fire alarm control panel can accommodate up to 128 Class B 64 Class A conventional zones and 48 Form C field programmable...

Page 70: ...X 012 Panel Strip Printer The AX 012 panel strip printer is an on board thermal strip printer for use with the AxisAX fire alarm control panel The AX 012 can be configured to provide automatic or on d...

Page 71: ...cians remote access through the Advanced AxisAX terminal dial up program to monitor maintain and perform service of a single AxisAX fire alarm control panel The AX MDM can either mount onto the four 4...

Page 72: ...n power limited circuit wiring Furthermore all power limited and non power limited circuit wiring must enter and exit the enclosure through different knockouts and or conduits see figure 46 Below is a...

Page 73: ...r only an additional 4A of load current for NAC 3 and NAC 4 is available Note The AX CTL 1PCB one loop base card cannot support the optional AX PSU expansion power supply module The AX CTL base card l...

Page 74: ...r both the quiescent condition and fire alarm condition for all loop devices By default a maximum of 5 detector LED indicators will be turned on in an alarm condition This number can be changed via th...

Page 75: ...he loop for both the quiescent condition and fire alarm condition for all loop devices By default a maximum of 5 detector LED indicators will be turned on in an alarm condition This number can be chan...

Page 76: ...ce to calculate the load on the loop for both the quiescent condition and fire alarm condition for all loop devices By default a maximum of 5 detector LED indicators will be turned on in a fire alarm...

Page 77: ...083334 hr Total Quiescent Current Ah Total Alarm Current Ah Total Load Quiescent Alarm Ah Total Load x 1 20 battery de rating factor Ah Converting Watts to Amps Utilizing Ohm s Law Amps Watts Volts c...

Page 78: ...ons are simultaneously acknowledged Global Acknowledgement RESOUND ALARMS Press to reactivate any silenced notification appliances connected to system NAC circuits or any output module of an SLC circu...

Page 79: ...ted from P A S configured devices will be delayed The delay can be extended for a further period by pressing the ACK button NFPA maximum delay time periods are Stage 1 time 15 seconds Stage 2 time 180...

Page 80: ...layed on the AX DSP alphanumeric graphic display during an alarm depending upon whether the event is acknowledged or unacknowledged and whether mass notification and or supervisory events are present...

Page 81: ...dicate the first alarm and a tally of any additional alarms mass notification and supervisory events To view additional alarm mass notification and supervisory events the user must scroll Scroll throu...

Page 82: ...nditions 7 2 2 1 Unacknowledged and Acknowledged Non Alarm Non MNS Events When the system registers a non alarm or non MNS event pre alarm warning supervisory and or trouble condition the event LED wi...

Page 83: ...DISBLs 0 TRBLs 2 Further device details Warnings Supervisory Disables and Troubles During unacknowledged non alarm and non MNS events the display only indicates the highest priority event and a tally...

Page 84: ...LED ZONE 0001 FIRST FLOOR MAIN LOBBY EXIT PULL STATION Press for device details WRNs 0 SUPRVs 0 DISBLs 1 TRBLs 0 New unacknowledged Disabled message Disabled zone text 32 Characters Disabled device te...

Page 85: ...back to the original alarm display When the Off Normal State Total display indicates Press to select pressing the check mark button on the keypad navigation keys will allow the user to view further d...

Page 86: ...acters type of device Press for device details WRNs 1 SUPRVs 0 DISBLs 0 TRBLs 0 Further device details Warnings Supervisory Disables and Troubles By pressing the right arrow button on the keypad navig...

Page 87: ...gisters a P A S Positive Alarm Sequence alarm the alarm LED will flash the internal buzzer will sound continuously the display will indicate NEW ALARM IN ZONE xxxx unacknowledged event the zone messag...

Page 88: ...n R 72 6 8 5 4 1 Alarm Verification 1 Applies to smoke detectors only Configuration must be password protected 2 It must not delay the actuation of alarms more than 60 seconds 3 Alarms from other devi...

Page 89: ...ication feature is not used Notification and other output signal circuits may be configured to only activate when two or more automatic devices within a detection zone enter an alarm condition At leas...

Page 90: ...isable NAC outputs or other output devices Groups 35 Group Disable Disable a programmed group of inputs outputs Controls 36 Cancel Level 2 panel access User ID 35 Return Level 2 access to the default...

Page 91: ...these pre dirty detector conditions can be view via the off normal area in addition to being transmitted via email from an optional AX LAN ipGateway 7 8 1 1 View Network This Option can be used to obt...

Page 92: ...current disabled condition mode for each input as either enabled or disabled In addition the SLC loop Lp address Adrs sector and node number Press the buttons to scroll through the inputs Pressing the...

Page 93: ...ss 001 Addr on Loop 1 Lp on Panel No 1 Node The device was in Zone 0001 The analog value registered by the device 64 has also been recorded The lower two lines show the zone description device text de...

Page 94: ...0 NAC 1 A 5 6V Normal 01 1 NAC 2 A 5 6V Normal 01 2 NAC 3 A 5 6V Normal 01 3 NAC 4 A 5 6V Normal Press the buttons to scroll through the panel internal circuits Press the Esc button to return to the...

Page 95: ...ual devices or all other devices If the current User ID access level password does not have the required authority the display prompts for entry of an authorized password to guard against inadvertent...

Page 96: ...ification none supervisory points including firefighter phones within the zone will be disabled and the Zone Mode status will change from Enabled to PART DISABLED 7 8 2 2 Disable Outputs The Disable O...

Page 97: ...and highlight the ONLY SELECTED OUTPUTS option and then press the button to select it ALL NACS NACS RELAYS ONLY SELECTED OUTPUTS The display then shows a list of Zones containing outputs For example 2...

Page 98: ...will be shown CONTROLS DISABLED ENABLE CONTROLS VIEW LED TEST STATUS The display will automatically revert to the normal operating display after 15 seconds 7 8 2 4 Disable User ID If User ID access i...

Page 99: ...been disabled The individual outputs within the zone can then be enabled ALL OUTPUTS NACS RELAYS ONLY SELECTED OUTPUTS 7 8 4 Test Menu Test Menu User 1 Node 1 ZONES DISPLAY BUZZER PRINTER OUTPUTS Not...

Page 100: ...hen an input device is activated i e pull station or introducing test smoke into a smoke detector the notification appliances will activate if selected and the display will indicate that a zone is reg...

Page 101: ...te Test Display also tests the LEDs of all of the Switch LED Modules connected to the associated AX CTL base card During this test it is possible to test the operation of the and 0 9 buttons When a bu...

Page 102: ...1 VIEW DISABLE ENABLE TEST P A S TOOLS STATUS If the P A S delays are configured in the panel the display shows the following pop up window when the P A S area is selected Note P A S delay functionali...

Page 103: ...re set as follows Interface Type RS232 Baud Rate 9600 Parity None Data Bits 8 Stop Bits 1 The following are printer capabilities within the Printer Menu Print Menu User 1 Node 1 INPUTS OUTPUTS TROUBLE...

Page 104: ...system Use the arrow buttons to highlight the first and last zone number and use the number keys to change the zone number required Press the key to start printing The display will show the following...

Page 105: ...rst Zone 1 Last Zone 5 Press to Start Print If there are zones with outputs disabled 1 Zone s with Outputs Disabled First Zone 1 Last Zone 5 Press to Start Print The panel will analyze the network and...

Page 106: ...etting and show the new value as it is entered For example SET TIME DATE TIME 1 PM DATE 04 15 14 SAT 15 APR 2006 If this panel is connected to a network all network node panels will adjust to the new...

Page 107: ...nects peripheral modules to AX CTL base card Twisted Unshielded or Twisted Shielded 5000 feet 18 20 AWG Twisted unshielded or twisted shielded wire is acceptable whenever the PBUS is wired internal an...

Page 108: ...resistance of both cable conductors 200mA 27 5 300mA 18 3 400mA 13 7 500mA 11 0 Note 2 Notification Appliance Circuit The voltage drop on notification appliance circuit should be calculated to ensure...

Page 109: ...fire alarm control panel provides integral electronic meters to check the operation of the batteries charger and input and output circuits The charging voltage and charging current can be read from t...

Page 110: ...d Current State of 3 rd SLC Loop Current 07 3 4 th SLC Load Current State of 4 th SLC Loop Current Dependent upon quiescent and alarm current draw of SLC devices per loop 08 0 1 st SLC V Out 23V Norma...

Page 111: ...life is shortened by increase in ambient temperature The life reduces by 50 for every 18 F 10 C rise above ambient Refer to battery manufacturer for further information Manufacturer Part Numbers YUASA...

Page 112: ...N Serial Expansion Card Connected 4 USB ON USB Connected 5 PBUS Communications Transmit Flashes when data transmitted to PBUS modules 6 PBUS Communications Receive Flashes when data received from PBUS...

Page 113: ...SLC 10 3 3 AX NET4 AX NET7 Network Module LED Function Description 1 Heartbeat LED Normal Flashes at 1Hz 2 Network Comms Receive Flashes when data received from network 3 Network Comms Transmit Flash...

Page 114: ...www advancedco com 114 10 3 5 AX PSU 6 Power Supply Charger There are seven 7 onboard LEDs associated with the AX PSU 6 Refer to the opposite diagram for LED descriptions and purpose...

Page 115: ...t 0 11 1 1 1 Intelligent Detector Drift Compensation The AxisAX intelligent detectors include compensation for sensor drift as part of the internal signal processing algorithm The algorithm will compe...

Page 116: ...etector tries to recalibrate and cannot maintain the programmed detector sensitivity a trouble signal Device Dirty for the specific detector will be generated at the AxisAX fire alarm control panel 11...

Page 117: ...es More Address Additional Info 001 0 EEP 1 23 002 0 003 0 EEP 1 21 004 0 EEP 1 22 Refer to the device data sheets for an explanation of the extended memory locations and for further information on th...

Page 118: ...vancedco com 118 100 South Street Hopkinton Massachusetts 01748 Tel 508 435 9995 Fax 508 435 9990 Email usa advancedco com Web www advancedco com Doc Number 682 001 AFS Revision 4 1 First Issued 2013...

Reviews: