Total Access
®
3000/3010 System Manual
6TADLP744-1E
TOTAL ACCESS 3000/3010
DLP-744
Page 12 of 12
© 2003, ADTRAN, Inc.
Perform Steps Below in the Order Listed
OC-3 MUX/VT1.5 Mapping – M13 1-to-1 Mapping
Provision STS-1 L2 MUX
STS-1 MUX/Provisioning/Linked Provisioning –
Enabled
(for redundant
operation)
STS-1 MUX/Provisioning/Clock Source –
Receive STS-1 Loop
STS-1 MUX/Provisioning/DCC Mode –
Disabled
STS-1 MUX/VT1.5 Mapping –
M13 1-to-1 Mapping
Repeat for second Expansion Shelf
Place Equipment In Service
Intelligent NE (Client) Shelf
OC-3 MUX/Provisioning/MUX Provisioning/MUX Service State –
In
Service
OC-3 MUX/Provisioning/EC-1 #1 Provisioning/Service State –
In Service
OC-3 MUX/Provisioning/EC-1 #2 Provisioning/Service State –
In Service
Repeat for OC-3 MUX B (if redundant configuration)
Expansion Shelf #1
STS-1 MUX A/Provisioning/Service State –
In Service
Repeat for STS-1 MUX B (if redundant configuration)
Expansion Shelf #2
STS-1 MUX A/Provisioning/Service State –
In Service
Repeat for STS-1 MUX B (if redundant configuration)