manualshive.com logo in svg
background image

Instruction Sheet

 

 

860660202     Rev. B     June 2021 

 

www.commscope.com 

  

 

 

 

 

 

© 2021 CommScope, Inc. All Rights Reserved  

Page 1 of 9  

All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This product may be covered by one or more U.S. patents or 

their foreign equivalents. For patents, see 

www.cs-pat.com

Visit our website a

www.commscope.com

 or contact your local CommScope representative for more information. 

For technical assistance, customer service, or to report any missing/damaged parts, visit us at: 

http://www.commscope.com/SupportCenter

 

 

                        Powered Fiber Cable Transition Box 

1.

 

General product information 

This document provides the installation procedure for the Powered Fiber Cable (PFC) Transition Box (TB). The 

TB is designed to facilitate the transition from indoor rated PFC to outdoor rated PFC in a neat and orderly 
fashion that maintains physical separation of the different media types.  See the 

CommScope 

Product 

Catalog for available configurations. 

 

2.

 

Tools and additional items required 

 

Round Cable Stripper 

 

Electrical Wire Stripper 

 

Large Flat Screwdriver  

 

Small Flat Screwdriver 

 

Power Drill/Driver (as needed) 

 

Fiber optic termination and cleaning supplies 

 

*

CommScope 

6 Port Fiber Adaptor in appropriate fiber mode (See Table 1) 

 

*

CommScope 

QWIK-FUSE Fiber Field Installable LC Connector Kits in appropriate fiber mode 

 

*

CommScope 

Furcation Tubing as required 

Material ID 

Description 

Fiber Mode 

Color 

760230938 

360DPis-12LC-LS 

MM 

AQUA 

760230946 

360DPis-12LC-SM 

SM 

BLUE 

760230953  360DPis-12LC-MM 

MM 

GRAY 

760230961  360DPis-12LCA-SM 

SM 

GREEN 

760236043 

360DPis-12LC-WB 

MM 

LIME GRN 

760242975 

360DPiP-12LC-LS 

MM 

AQUA 

760242976  360DPiP-12LC-SM 

SM 

BLUE 

760242977  360DPiP-12LC-WB 

MM 

LIME GRN 

760242978  360DPiP-12LCA-SM 

SM 

GREEN 

       Table 1 – Recommended 

CommScope

 6 Port Fiber Adaptors 

 

*Can be ordered fro

www.commscope.com 

 

Содержание 760230938

Страница 1: ...ated PFC in a neat and orderly fashion that maintains physical separation of the different media types See the CommScope Product Catalog for available configurations 2 Tools and additional items required Round Cable Stripper Electrical Wire Stripper Large Flat Screwdriver Small Flat Screwdriver Power Drill Driver as needed Fiber optic termination and cleaning supplies CommScope 6 Port Fiber Adapto...

Страница 2: ...s and connectivity label The G2 6 port fiber adapter can be ordered separately from www commscope com The TB is designed to accommodate up to six 6 PFC channels with each channel consisting of two power conductors and and one duplex fiber connection TX TR The TB is designed for indoor use and may be located in the plenum space Cable can enter the box through fire foam lined cable slots or through ...

Страница 3: ...ion hardware must match the intended application with a minimum pull out requirement of 20 lbs f 88 N per hardware location 2 Attach 12 AWG or larger ground wire to the TB using the green ground screw as shown in Figure 1 Attach wire to Earth ground 3 Secure the ground wire to the strain relief bar with a supplied cable tie as shown in Figure 2 4 Insert the 6 port fiber adapter into the G2 opening...

Страница 4: ...PFC into the TB and secure to the strain relief bar with a supplied cable tie as shown in Figure 4 Ensure adequate length for fiber slack 1 1 5 meters 2 Strip the outer jacket of the PFC using a round cable stripper so that there is approximately 25mm of jacket extending inside the box as shown in Figure 5 Trim any strength members or other cable components except for power conductors and fibers F...

Страница 5: ...als until the wires insert into the terminal ports Push each wire into its port Screw each terminal down hand tight to make contact between the terminal and the wire conductor Verify the wires are secure in the terminals with no exposed wire conductor as shown in Figure 7 6 Terminate the LC Fiber Optic plugs see section 2 per the product specifications instructions Visit www commscope com for LC C...

Страница 6: ...cable tie as shown in Figure 9 Ensure adequate length for fiber slack 1 1 5 meters 2 Separate the cable into three sections along the tear lines as shown in Figure 9 3 For the outgoing power termination repeat steps 3 5 from Section 6 Step 1 verifying any end device powered equipment wiring polarity with polarity connections on terminal strip as shown in Figure 10 Note Polarization indentation alo...

Страница 7: ...LC Connector application instructions and tool kit information Note Furcation tubing can be used to protect coated fiber Visit www commscope com for a variety of colors 5 Clean and install the LC terminations into the adapter see installation and cleaning instructions TECP 96 194 Store excess fiber slack on the spool as shown in Figure 11 6 Repeat steps 1 5 for all outgoing PFCs Figure 9 Figure 10...

Страница 8: ...ver 1 Fix the connectivity label to the inside or outside of cover and record the channel information as needed 2 Place the cover over the loose screw heads with the warning label facing outward and slide into place tighten the cover screws to secure as shown in Figure 12 Revision history Rev A Initial release Rev B 40132706CMO Figure 12 ...

Страница 9: ...860660202 Rev B www commscope com Instruction Sheet 2021 CommScope Inc All Rights Reserved Page 9 of 9 ...

Отзывы: