6TASYS101-1E
TOTAL ACCESS 3000/3010
SYS-101
Page 19 of 46
Total Access
®
3000/3010 System Manual
© 2003, ADTRAN, Inc.
The OC-3 incorporates these features:
•
Supports DCC management channel
•
Provides 1:1 OC-3 equipment and facility protection switching
•
Detects and indicates standard optical and SONET alarm and loopback
conditions
•
External, line, loop or local timing modes
•
Linked Provisioning option
Faceplate LED indicators include:
•
Power
•
Status
•
Optics
•
Test
•
Clock
•
Lockout
•
On Line
Other faceplate features include:
•
Automatic Protection Switch (APS) push-button
•
Test/Enable
4.3 Access Modules
Total Access 3000/3010 incorporates a complete array of local loop access
technologies into an integrated intelligent system. Access modules include those
servicing both optical and metallic local loops. Most access modules occupy one slot
in the Total Access shelf. Those devices that occupy more than one slot will be
specifically identified.
A 1:1 Automatic Protection Switching (APS) option will place two identical modules
in adjacent slots into an online/standby status. The main unit occupies any
odd-numbered slot and its auxiliary unit occupies the next higher even-numbered slot.
Failure events with the online loop or device will enable a protection switch.
Protection is not available on the double-wide HD-10 for ISDN.
To facilitate full integration, Total Access 3000/3010 technology is compatible or
identical in function with existing ADTRAN products. Screen displays and menus are
consistent with the look and feel of other ADTRAN displays to ensure operator
familiarity.