Perform Steps Below in the Order Listed
3. As an example, from the Daily Threshold Menu select option 1,
Code
Violation…….L
, and press <Enter>.
1.
Set Alarm Threshold
2.
Set Alarm Enable
Set the Alarm Threshold and then Enable the alarm to be issued if the set threshold
value is exceeded.
4. Return to the Performance Monitoring Menu by pressing <Esc>.
5. From the Performance Monitoring Menu select option 6,
Far-End Daily
Threshold
, and press <Enter>.
1.
Code Violation…………… CP-P
2.
Errored Second………….. CP-P
3.
Severely Errored Second…CP-P
4.
Unavailable Second……... CP-P
6. For an example, from the Far-End Daily Threshold Menu select option 2,
Errored
Second……CP-P
, and press <Enter>.
1.
Set Alarm Threshold
2.
Set Alarm Enable
Set the Alarm Threshold and then Enable the alarm to be issued if the set
threshold value is exceeded.
7. Return to the Working MUX Main Menu by pressing <Esc> and proceed to the
next section.
1.5
Protection Configuration Provisioning
This provisioning option is only used when two DS-3 MUX Modules are installed and
will be used in a protection switching configuration. Please proceed with the following
steps to provision protection switching on the working MUX. If the MUX is in a single
configuration, please continue this procedure at Section 5,
Channel Mapping
Provisioning
.
1. From the Working MUX Main Menu select option 7,
Protection Configuration
,
and press <Enter>.
2. From the Protection Configuration Menu select option 3,
BER Line Switch
, and
press <Enter>.
This option “INHIBITS” or “ALLOWS” APS operation based on the Bit Error