Total Access
®
3000/3010 System Manual
Perform Steps Below in the Order Listed
1.8
Display Options
Display Options allows the user to format the output display of the MUX Menu
screens to their preference. The available settings are listed below.
1
From the Primary MUX Main Menu select option 11,
Display Options
, and press
<Enter>.
1.
VT Number Display Format
2.
High ASCII Characters
3.
Screen Height
4.
Screen Width
Select the desired option by typing the corresponding number and press <Enter>.
2. Return to the Primary MUX Main Menu by pressing <Esc>.
This concludes the procedure for provisioning a single MUX in a non-protection
configuration or the Primary MUX in a protection configuration. Please proceed to
Section 2.10
for provisioning the Protect MUX in a protection configuration or
to place the units In-Service.
1.9
Preparing to Provision the Protect MUX (slot B)
Ensure that Linked Provisioning is “Enabled” on the Primary MUX before proceeding.
The factory default setting for Linked-Provisioning is “Enabled” and should be already
set. The procedure to access this feature is listed below for convenience.
1. From the Total Access Main Menu, select option 2,
Common A - [OC-3 MUX]
,
and press <Enter>. This will be the menu tree for the OC-3 MUX in slot A.
2. From the OC-3 MUX A Menu, select option 2,
Provisioning
, and press <Enter>.
Check to see if Linked Provisioning Enabled or Disabled. To enable, continue with
the next two steps.
3. From the Provisioning Menu, select option 5,
Linked Provisioning
, and press
<Enter>.
4. From the Linked Provisioning Menu, select option 2,
Enable
, and press <Enter>.
5. Return to the Total Access Main Menu by pressing <Esc>.
The Protect MUX must first be placed in the OOS, Maintenance service state before
Linked Provisioning automatically provisions the unit. Perform the following
procedure to place the module in the OOS, Maintenance mode.