Chapter 5. Using the Terminal Menu
5-50
ATLAS
_
800
PLUS
User Manual
61200226L1-1
.
Quad Nx56/64 Module (User Termination)
When you are working in the
User Termination
section of the
Dial Plan
menu, and
the
Slot
is defined as a QuadNx56/64 module, the following interface configura-
tion options are available:
Ports Available
Indicates which of the four ports of the Quad Nx56/64 module have already been
defined either in another switched end point (indicated by “s”) or in a Dedicated
Map (indicated by “n”). This field is read-only.
Number of Ports
Defines to ATLAS how many of the ports could be used to answer calls to the
number(s) defined in the Accept Call list. You can enter numbers 1 through 4. The
ports are contiguous beginning with the Port number select and the number of
ports.
Example:
If the port selected (as a part of Slot/Port selection) is 2, and the number of
ports selected here was 2, then ports 2 and 3 would be enabled to receive calls
to the numbers listed under the Incoming Call Accept list.
Octal BRI Module Configuration
This section describes the
Network Termination
and
User Termination
configuration
settings for Octal BRI module when using the
Dial Plan
menus.
Octal BRI Module (Network Termination)
The Octal BRI with a “U” interface can interface directly to the Network (PSTN).
When you are working in the
Network Termination
section of the
Dial Plan
menu
and the
Slot
is defined as a UBRI-8 option module, the following interface config-
uration options are available:
Switch Type
Write security: 2; Read security: 5
Defines the type of ISDN switch that ATLAS is connected to. If connected to
another ATLAS, both need to be set to the same type. Choices include the follow-
ing:
•
Lucent 5E
•
Northern DMS 100
•
National ISDN
SPID List
Write security: 2; Read security: 5
In order to properly operate with a network (PSTN) ISDN switch, the BRI inter-
face must have SPID (Service Profile Identifier) and phone number(s) that match
the SPID(s) and Phone number(s) which have been programmed into the ISDN
The Quad Nx56/64 can only serve as a user termination end point
Summary of Contents for ATLAS 800PLUS
Page 1: ...ATLAS 800PLUS USER MANUAL Part Number 1200226L1 61200226L1 1A September 1998...
Page 10: ...x ATLAS 800PLUS User Manual 61200226L1 1...
Page 16: ...List of Figures xvi ATLAS 800PLUS User Manual 61200226L1 1...
Page 18: ...List of Tables xviii ATLAS 800PLUS User Manual 61200226L1 1...
Page 26: ...Chapter 1 Introduction 1 8 ATLAS_800PLUS User Manual 61200226L1 1...
Page 52: ...Chapter 4 Front Panel Operation and Menu Structure 4 10 ATLAS_800PLUS User Manual 61200226L1 1...
Page 116: ...Chapter 7 Creating a Dial Plan 7 8 ATLAS 800 PLUS User Manual 61200226L1 1...
Page 164: ...Index Index 12 ATLAS 800 PLUS User Manual 61200226L1 1A...
Page 166: ......