S
YSTEM
C
ONFIG
> S
YSLOG
> VOATM L
EVEL
Minimum required level for sending Voice-over-ATM log messages. VoATM messages provide status
information concerning the FXS (or FXO for Total Access 624 units only) voice signaling occurring over
the ATM link.
S
YSTEM
C
ONFIG
> S
YSLOG
> PPPOA L
EVEL
Minimum required level for sending PPP-over-ATM log messages. PPPoA log messages provide status
information concerning PPP packets being sent and received over the ATM link.
S
YSTEM
C
ONFIG
> S
YSLOG
> FDL L
EVEL
Minimum required level for sending FDL log messages. FDL log messages provide status information
concerning the operation of the FDL link.
S
YSTEM
C
ONFIG
> S
YSLOG
> F
ILTER
Minimum required level for sending Filter log messages.
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
Activate the network time and configure the server type, time zone and various other network time
parameters from this menu.
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
> S
ERVER
T
YPE
The unit time can be entered manually from the
S
YSTEM
I
NFO
menu, or the unit can receive time from an
NTP/SNTP server. The
N
ETWORK
T
IME
menu includes all parameters relating to how the unit
communicates with the time server.
The server type defines the port on which the unit will listen to receive timing information from the time
server. The choices are
NT T
IME
and
SNTP
. When set to
NT T
IME
, the unit will receive time from an NT
server running SNTP software on its TIME port. When set to
SNTP
, the unit will receive time directly
from an SNTP server. The factory default is
SNTP
.
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
> A
CTIVE
This network timing feature can be turned on and off. It determines whether the unit will request and
receive time from a time server. The factory default is
N
O
.
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
> T
IME
Z
ONE
All time zones are based off of Greenwich Mean Time (GMT). The choices are listed below.
•GMT
•GMT -5 (E
ASTERN
)
•GMT -6 (C
ENTRAL
)
•GMT -7 (M
OUNTAIN
)
•GMT -8 (P
ACIFIC
)
•GMT -9 (A
LASKA
)
•GMT -10 (H
AWAII
)
The factory default is
GMT-6 (C
ENTRAL
)
.
Summary of Contents for 606
Page 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Page 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Page 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Page 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Page 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Page 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Page 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Page 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...