Section 5 DLP-17
Total Access 600 Series System Manual
232
© 2004 ADTRAN, Inc.
61200624L1-1B
1. Connect the Total Access 6XX unit to your VT100 system (details found in DLP-1,
Connecting a
VT100 Terminal or PC to the CRAFT Port
).
2. Log in to the system with maximum rights (details are in DLP-2,
Logging in to the System
).
3. From the
DS0 M
APS
menu, select the
A
CTIVE
M
AP
option and press
<Enter>
.
4. From the
DS0 M
APS
> A
CTIVE
M
APS
menu, select the
D
UAL
T1 M
AP
option; press
<Enter>
. Select “Y”
for yes to confirm the Active Map change and press
<Enter>
. The following screen appears.
Figure 1. Dual T1 Map
Perform the steps below in the order listed.
The second T1 connected to the DSX port may only be used for voice connections
(FXS/FXO).
Summary of Contents for 606
Page 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Page 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Page 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Page 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Page 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Page 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Page 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Page 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...