1. Connect the computer to the Total Access 6XX
CRAFT
interface (details in DLP-1,
Connecting a
VT100 Terminal or PC to the CRAFT Port
).
2. Log in to the unit.
3. Select the
S
YSTEM
C
ONFIG
/M
ANAGEMENT
/T
ELNET
A
CCESS
menu and set the
T
ELNET
A
CCESS
to
O
N
.
4. Under the
S
YSTEM
C
ONFIG
/M
ANAGEMENT
/T
ELNET
A
CCESS
menu, select the
T
ELNET
U
SER
L
IST
; press
<Enter>
. The following screen appears.
5. Use the right arrow key to select the N
AME
field; press
<Enter>
. All new Telnet entries have a
I
NACTIVE
as the
N
AME
. Enter a specific username to use for Telnet login. Each Telnet entry in the list must have
a unique assigned name because duplicate names are not allowed.
6. Use the right arrow key to select
P
ASSWORD
; press
<Enter>
. Enter a password to use for Telnet logins.
7. Use the right arrow key to select
I
DLE
T
IME
(
MINS
)
; press
<Enter>
. This field defines the amount of time
in minutes the Telnet session may be idle before the user is logged off. The range is 1-255 and the
default value is 10 minutes. Enter the appropriate
I
DLE
T
IME
.
8. Use the right arrow key to select
L
EVEL
; press
<Enter>
. Select the appropriate security level.
(Reference DLP-6,
Adding/Removing Users and Changing Password Security Levels
, for security
level definitions.)
9. This completes the addition of one Telnet user. Repeat steps 1-11 for each additional Telnet user
access.
10. Press the left arrow key to escape out to the main menu. This saves your changes.
Perform the steps below in the order listed.
The presence of an asterisk in the lower right corner of the menu window indicates that
changes have NOT been saved to flash memory. Changes are automatically saved to flash
as the user backs out of the menu system or after a manual save (by pressing
<CTRL+W>
.
Always ensure that the asterisk is not present before logging off the system. Failure to save
changes could result in a configuration loss if a power failure occurs. (For more details on
the asterisk indicator, refer to Config Status on page 45.
Summary of Contents for 606
Page 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Page 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Page 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Page 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Page 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Page 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Page 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Page 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...