61200624L1-1B
© 2004 ADTRAN, Inc.
189
DLP-3 Setting IP Parameters
Introduction
If the Total Access 6XX is connected to an IP network for Telnet, TFTP, or SNMP management, there are
several IP parameters which must be set for the unit to communicate with the network. These parameters
are described in this DLP along with the procedures for setting them.
Prerequisite Procedures
This procedure assumes that the Total Access 6XX unit is connected to an IP network and is powered up.
Tools and Materials Required
•
VT100 compatible terminal or computer with terminal emulation software
•
Appropriate cable to connect terminal to the Total Access 6XX (customer-provided).
•
DB-9 female to RJ-48 female adapter (ADTRAN proprietary) for connecting to the
CRAFT
port on the
rear of the unit (see
CRAFT Port
on page 31).
The Total Access 6XX comes pre-programmed for default Telnet access. The following IP
parameters apply:
•
IP Address: 10.0.0.1
•
Subnet Mask: 255.255.255.0
•
User: guest
•
Password: password
For security purposes, change the default Telnet password during the initial unit
configuration. (Refer to System Config > Management > Telnet Access > User List on
page 53 for more details.)
Please see your Network Administrator for the proper assignment of the following
parameters:
IP A
DDRESS
,
S
UBNET
M
ASK
, and
D
EFAULT
G
ATEWAY
.
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
Electronic equipment can be damaged by static electrical discharge. Before handling
modules, put on an antistatic discharge wrist strap to prevent damage to electronic
components. Place equipment in antistatic packing material when transporting or storing.
When working on equipment, always place it on an approved antistatic mat that is
electrically grounded.
Summary of Contents for 606
Page 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Page 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Page 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Page 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Page 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Page 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Page 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Page 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...