2. Configuring the Layer 2 Protocol
For more details on the configuration parameters discussed in this section, refer to the following pages:
Layer 2 Frame Relay Protocol menus beginning on
page 93
Layer 2 PPP Protocol menus beginning on
page 91
Layer 2 Ethernet menus beginning on
page 116
Ethernet Interface Setup Instructions
Most applications should not require a manual setup for the Ethernet interface. By
default, the Ethernet interface is configured to auto-detect the data rate (as either 10
or 100 Mbps). The following steps disable the auto-negotiation parameter and
manually configure the interface.
Step
Action
1
From the main menu, select
I
NTERFACES
.
2
Highlight the
C
ONFIG
menu for the
ETH
interface and press
<E
NTER
>
.
3
Use the right arrow to select
A
UTONEGOTIATION
and press
<E
NTER
>
. Use the
down arrow to choose
OFF
.
4
Select the
D
ATA
R
ATE
field and specify either
10B
ASE
T
or
100B
ASE
T
.
5
Select the
D
UPLEX
T
YPE
field and specify either
H
ALF
D
UPLEX
or
F
ULL
D
UPLEX
.
Layer 2 Protocol (FRE) Configuration – T1 Interface
Step
Action
1
From the main menu, select
L2 P
ROTOCOL
and press
<E
NTER
>
.
2
Use the arrow keys to select the
P
ROTOCOL
field for the
T1
interface. Press
<E
NTER
>
. Select
FRE
from the list of available protocols.
3
Highlight the
C
ONFIG
menu for the
T1
interface and press
<E
NTER
>
.
4
Set the
M
AINTENANCE
P
ROTOCOL
to
A
NNEX
D
(ANSI)
, A
NNEX
A
(q933a)
, LMI,
OR
S
TATIC
(no sig).
The
M
AINTENANCE
P
ROTOCOL
should be set based on the Frame Relay switch.
5
Down arrow and press
<E
NTER
>
on
DLCI M
APPING
. Press the right arrow key to
create an entry. To create additional entries, highlight the
N
UM
field and press
the
<I>
key. To delete an entry, highlight the
N
UM
field for the entry to delete
and press the
<D>
key.
6
Set
A
CTIVE
to
Y
ES
.
Summary of Contents for 606
Page 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Page 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Page 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Page 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Page 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Page 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Page 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Page 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...