Total Access 600 Series System Manual
Section 4 User Interface Guide
61200624L1-1B
© 2004 ADTRAN, Inc.
155
3. Setting the Router Options
For more details on the configuration parameters discussed in this section, refer to the following pages:
Router Ethernet Interface Configuration menus beginning on
page 119
Router Network Interface Configuration menus beginning on
page 122
Router Default Gateway menus beginning on
page 128
3
Set mode to
R
OUTE
IP
. Using this menu you also have the option to route only
IP packets and bridge all other data packets (
R
OUTE
IP/B
RIDGE
O
THER
) or
bridge all data packets on this connection (
B
RIDGE
A
LL
). Refer to
L2 Protocol
(ALL–ETH–802.3) > Config > Mode
on page 116 for more details.
4
Left arrow back to the main menu to save the changes.
Router Options – Ethernet Interface
Step
Action
1
From the main menu, select
R
OUTER
and press
<E
NTER
>
.
2
Use the right arrow key to highlight
C
ONFIG
and press
<E
NTER
>
.
3
Select
I
NTERFACES
and press
<E
NTER
>
. Use the right arrow key to highlight the
S
ETUP
field for the
ETH
(Ethernet) interface and press
<E
NTER
>
.
4
Highlight the
P
RIMARY
IP
field and press
<E
NTER
>
.
5
Set the
IP A
DDRESS
of the Ethernet port.
6
Set the
S
UBNET
M
ASK
for the Ethernet port.
7
By default, RIP is disabled on the Ethernet interface. If RIP needs to be
enabled, highlight the
RIP
field and press
<E
NTER
>
. Set the appropriate
V
ERSION
,
RIP M
ETHOD
,
D
IRECTION
, and
V2 S
ECRET
(where applicable) to
configure RIP on the interface. For more details, refer to
Router > Config >
Interfaces (ETH) > Sub-Interface
on page 120.
8
Press the left arrow key to return to the Ethernet sub-interface menu (displays
P
RIMARY
IP
and
S
ECONDARY
IP
).
9
If your application requires additional secondary IP address, highlight the
S
ECONDARY
IP
field and press
<E
NTER
>
. The Total Access 6XX supports up to
5 additional LAN segments. Enter each additional secondary IP address and
corresponding subnet mask. To add a new IP address entry, highlight the
N
UM
field and press the
<I>
key. To delete an existing entry, highlight the
N
UM
field
for the entry to delete and press the
<D>
key.
10
Left arrow back to the main menu to save the changes.
Layer 2 Protocol Configuration – Ethernet Interface
Summary of Contents for 606
Page 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Page 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Page 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Page 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Page 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Page 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Page 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Page 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...