Total Access 600 Series System Manual
Section 4 User Interface Guide
61200624L1-1B
© 2004 ADTRAN, Inc.
151
DS0 M
APS
> E
DIT
/V
IEW
M
AP
1 > RBS
Voice applications require signaling information to identify the state of the channel. In some voice
networks a dedicated signaling channel is available to accomplish this (for example, ISDN with a
dedicated D channel). Traditional voice networks may employ Robbed Bit Signaling (RBS), also known as
Channel Associated Signaling (CAS), where a dedicated signaling channel is unavailable. RBS
permanently encodes signaling information by “robbing” a single bit from designated T1 frames and using
them as signaling information carriers. The actual location of the signaling information within the T1
frame depends on the framing format of the T1 circuit. For SuperFrame (SF) framing, the T1 channel is
comprised of 12, 193-bit frames (192 data bits plus a single framing bit). RBS “robs” the framing bits from
the even numbered frames (2, 4, 6, etc) to provide signaling information for that channel. The signaling
bits provided in these frames are known as the A and B signaling bits.Voice termination devices use the
various combinations of the signaling bits to identify the current state of the voice circuit. Each signaling
type (Loop Start, Ground Start, E&M, etc) uses varying combinations of A and B bits to identify the
various states of the circuits such as ringing, on-hook, and off-hook. Extended Superframe (ESF) framing
is similar to SF in operation. Each ESF T1 channel is comprised of 24, 193-bit frames (192 data bits plus a
single framing bit) and allows bit “robbing” in frames 6, 12, 18, and 24. These signaling bits are known as
the A, B, C, and D signaling bits, respectively. Again, voice termination devices use the various
combinations of the signaling bits to identify the current state of the voice circuit.
The default value for this parameter is
N/A
. Once a port is assigned to a service (using the
S
ERVICE
field),
this parameter changes to
O
N
or
O
FF
(depending on the selected service).
O
N
preserves the signaling bits
between the connections and is typically required for analog voice connections; therefore, for FXS
interfaces,
RBS
defaults to
O
N
. Additionally, when passing voice circuits with in-channel signaling
through to the DSX-1 interface, signaling bits are preserved by setting
RBS
to
O
N
. For clear channel
service to the DSX-1 interface (for voice circuits with a dedicated signaling channel and all data) set
RBS
to
O
FF
(which ignores the signaling bits). When
S
ERVICE
is set to
T1 IAD
, the
RBS
parameter remains at
N/A
because
RBS
is not applicable to data connections.
Map 2 menus are identical to Map 1. Please use the menu explanations above for Map 2.
Summary of Contents for 606
Page 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Page 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Page 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Page 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Page 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Page 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Page 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Page 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...