Section 4 User Interface Guide
Total Access 600 Series System Manual
52
© 2004 ADTRAN, Inc.
61200624L1-1B
S
YSTEM
C
ONFIG
> M
ANAGEMENT
> CRAFT P
ORT
> I
DLE
T
IME
This option defines the amount of time in minutes user may stay connected without any activity on the
CRAFT
port before the user is automatically logged out of the system. A value of
0
disables this inactivity
timer function enabling users to stay connected until manually logged out. The value range is
0
(def) to
255
(minutes).
S
YSTEM
C
ONFIG
> M
ANAGEMENT
> CRAFT P
ORT
> B
AUD
R
ATE
This is the asynchronous rate that the
CRAFT
port will run. The possible values are
300
,
1200
,
2400
,
4800
,
9600
,
19200
,
38400
,
57600
,
and
115200
. The default value is
9600
. The unit and the VT100 terminal or
PC with terminal emulation software must be set for the same baud rate.
S
YSTEM
C
ONFIG
> M
ANAGEMENT
> CRAFT P
ORT
> D
ATA
B
ITS
The number of data bits that the
CRAFT
port sends in a frame. The possible values are
7
or
8
(def) bits. The
unit and the VT100 terminal or PC with terminal emulation software must be set for the same number of data
bits.
S
YSTEM
C
ONFIG
> M
ANAGEMENT
> CRAFT P
ORT
> P
ARITY
This is the asynchronous parity that the
CRAFT
port will run. The possible values are
N
ONE
(def),
O
DD
, or
E
VEN
. The unit and the VT100 terminal or PC with terminal emulation software must have the same parity
setting.
S
YSTEM
C
ONFIG
> M
ANAGEMENT
> CRAFT P
ORT
> S
TOP
B
ITS
This is the number of stop bits used for the
CRAFT
port. The possible values are
1
(def),
1.5
or
2
. The unit
and the VT100 terminal or PC with terminal emulation software must have the same number of specified
stop bits.
S
YSTEM
C
ONFIG
> M
ANAGEMENT
> T
ELNET
A
CCESS
Activate the Telnet access and set up the various Telnet parameters from this menu. The Total Access 6XX
supports up to five simultaneous Telnet sessions.
Table 2. Instructions for Changing Passwords
Step
Action
1
Select the
P
ASSWORD
field—a new
P
ASSWORD
field displays.
2
Type the new password in the
E
NTER
field.
3
Type the new password again in the
C
ONFIRM
field.
The Total Access 6XX ships with default Telnet Access parameters of: guest (user),
password (password). Change this password during the initial configuration to protect
your unit.
Summary of Contents for 606
Page 14: ...Table of Contents Total Access 600 Series System Manual 14 2004 ADTRAN Inc 61200624L1 1B ...
Page 196: ...Section 5 DLP 4 Total Access 600 Series System Manual 194 2004 ADTRAN Inc 61200624L1 1B ...
Page 204: ...Section 5 DLP 6 Total Access 600 Series System Manual 202 2004 ADTRAN Inc 61200624L1 1B ...
Page 208: ...Section 5 DLP 7 Total Access 600 Series System Manual 206 2004 ADTRAN Inc 61200624L1 1B ...
Page 222: ...Section 5 DLP 13 Total Access 600 Series System Manual 220 2004 ADTRAN Inc 61200624L1 1B ...
Page 232: ...Section 5 DLP 16 Total Access 850 System Manual 230 2004 ADTRAN Inc 64203376L1 1A ...
Page 240: ...Section 5 DLP 18 Total Access 600 Series System Manual 238 2004 ADTRAN Inc 61200624L1 1B ...
Page 244: ...Section 5 DLP 19 Total Access 600 Series System Manual 242 2004 ADTRAN Inc 61200624L1 1B ...