Section 2: Mounting and Wiring
2-3
4. Connect the (–) terminal of the supplementary power supply to header position 2 (GND
terminal of Symphony/Symphony-i (black wire)).
5. Connect the Data In terminal of the control panel to header position 3 (Data Out
terminal of Symphony/Symphony-i (green wire)).
6. Connect Data Out terminal of the control panel to header position 4 (Data In terminal of
Symphony/Symphony-i (yellow wire)).
7. Connect one end of the Ethernet cable (Category 5) to Symphony/Symphony-i 's RJ45
Ethernet connector and the other end as follows:
If using …
Then …
broadband (e.g. cable modem, DSL, etc.)
connect to cable/DSL router
narrow band (dial-up modem)
connect to 8950T
You may want to reference cable wiring information for RJ45 cable. For Category 5 cable pin
outs, refer to the System Interconnection Diagram supplied.
8. Attach the case front of Symphony/Symphony-i to the case back. Attach the top of
Symphony/Symphony-i first, and then press the bottom section inward until it snaps into
place securely.
If using a 9-pin connector, connect the wires to the header as follows:
1. Connect the (+) terminal of the supplementary power supply to header position 1
(+12VDC terminal of Symphony/Symphony-i (red wire)).
2. Connect the (–) terminal of the supplementary power supply and the Gnd terminal of the
control panel to header position 3 (Gnd terminal of Symphony/Symphony-i (black wire)).
3. Connect the +12V terminal of the control panel to header position 2 (+12VDC terminal of
Symphony/Symphony-i (red wire)).
4. Connect the Data In terminal of the control panel to header position 4
(Symphony/Symphony-i Data Out terminal (green wire)).
5. Connect the Data Out terminal of the control panel to header position 5
(Symphony/Symphony-i Data In terminal (yellow wire)).
6. Connect the 485 Video bus wires (if video is available and will be used) to header
positions 8 and 9 (the audio bus terminals of Symphony/Symphony-i).
7. Connect one end of the Ethernet cable (Category 5) to Symphony/Symphony-i 's RJ45
Ethernet connector and the other end as follows:
If using …
Then …
broadband (e.g. cable modem, DSL, etc.)
connect to cable/DSL router
narrow band (dial-up modem)
connect to 8950T
You may want to reference cable wiring information for RJ45 cable. For Category 5 cable pin
outs, refer to the System Interconnection Diagram supplied.
8.
Attach the case front of Symphony/Symphony-i to the case back. Attach the top of
Symphony/Symphony-i first, and then press the bottom section inward until it snaps into
place securely.
Phone Line Connections
Summary of Contents for 8132
Page 2: ......
Page 14: ...Symphony Symphony i Installation and Setup Guide 3 4...
Page 42: ...Symphony Symphony i Installation and Setup Guide 4 28...
Page 56: ...Symphony Symphony i Installation and Setup Guide 6 8...
Page 60: ...Symphony Symphony i Installation and Setup Guide 7 4...
Page 76: ...Symphony Symphony i Installation and Setup Guide 8 16...
Page 78: ...Symphony Symphony i Installation and Setup Guide 9 2...
Page 80: ...Symphony Symphony i Installation and Setup Guide 10 2...
Page 83: ...NOTES...
Page 84: ...NOTES...
Page 85: ...NOTES...
Page 86: ...NOTES...
Page 87: ......
Page 88: ...165 Eileen Way Syosset NY 11791 Copyright 2002 Pittway Corporation 9 l K5762V6 12 02...