Symphony/Symphony-i Installation and Setup Guide
5-4
SCREEN ACTION
9. Summary of the zone's current
programming. ZT=Zone Type, P=Partition,
RC=Report Code, IN=Input type and L=loop
number. No entry required. Press [*] to
continue.
10. Enter the zone type desired for
supervision of AlarmNet-i (or change it, if
necessary). We recommend using Zone Type
5 (Trouble by Day/Alarm by Night) or Zone
Type 19 (24-HR Trouble). Press [*] to
continue.
11. Enter the report code. The report code
consists of 2 hexadecimal digits, each in turn
consisting of 2 numerical digits. For example,
for a report code of "3C," enter 03 for "3" and
12 for "C." (Refer to
System Communication
section in VISTA-50PEN II)
Press [*] to continue.
12. Scroll through the menu options by
repeatedly pressing 0 until DEVICE PROG?
appears.