8.5.4.3 readpower - Read power
Command
readpower value
Function
Check (no value) or change the read power in dBm.
Description
The reader in Standalone mode can have the read power range from 0 to 15 dBm.
Pattern
10 dBm
Values
0 .. 15
Example
To check the reading power:
readpower<CR>
12<CR>
To change the reading power to 5 dBm:
5<>CR
ok - parameter has been changed.<CR>
Errors
When the value reported is not among the specified:
error - value out of range<CR>
When more than one value is passed to the command:
error - too many args.<CR>
NOTE:
The reader will reach and its power consumption, we always recommend
adjusting the best reading power according to your application.