Rev. 1
HEXAPAD 10 BC USB
8.5.4.5 rfoff - Downtime
Command
rfoff value
Function
Check (no value) or change the read interval time in ms (milliseconds).
Description
The reading interval time is equivalent to the time when the reader turns off the RF power
on your antenna.
Pattern
250 ms
Values
0 .. 1000
Example
To check the read interval time:
rfoff<CR>
250<CR>
To change the reading interval time to 500 ms (0.5 s):
500<CR >
ok - parameter has been changed.<CR>
Errors
When the value reported is not among the specified:
error - value out of range<CR>
When more than one value is passed to the command:
error - too many args.<CR>
NOTE:
The
reading results are reported by the reader after the sum of rfon rfoff times.