actiLib Library 4U
– User and Service Guide
Page 83 of 103
Timer unit has failed during POST.
several occurrences contact
technical support
D4
UART Error.
Frame overrun or Parity Error on serial Interface.
Retry operation; after
several occurrences contact
technical support
D5
Display Error
Communication to display failed
Retry operation; after
several occurrences contact
technical support
D6
Memory Error, Stack and heap overflow.
Retry operation; after
several occurrences contact
technical support
D7
Fatal system error
Retry operation; after
several occurrences contact
technical support
D8
Data base error
Retry operation; after
several occurrences contact
technical support
D9
No SCSI IC detected
Retry operation; after
several occurrences contact
technical support
DA
In Library Verify Test the barcode reader has
read different barcode data for the same
cartridge label
Check barcode label on
scratch cartridge and run
Library Verify Test again. If
the error recurs, contact
technical support
DB
Warning event!
See section below
DC
I²C Bus Failure
Retry operation; after
several occurrences contact
technical support
DD
Warning event!
See section below
DE
Warning event!
See section below
DF
Warning event!
See section below
E0
Incompatible magazine detected
Check type of lowest left
magazine
F0
Drive Overtemperature Condition
The subcode indicates which drive is affected
Example:
Subcode 01: drive #1
Check ambient temperature
conditions and check all
fans, after several
occurrences contact
technical support