actiLib Library 4U
– User and Service Guide
Page 22 of 103
6
Installing the actiLib Library 4U
6.1
Location requirements
Choose a location that meets the following criteria
Criteria
Definition
Rack requirements
Standard 19-inch rack with 4U of clearance
Room temperature
10-35º C (50-95º F)
Power source
AC power voltage: 100-127 VAC; 200-240 VAC
Line frequency: 50-60 Hz
Place the Library near an AC outlet. The AC power cord is the
product’s main AC disconnect device and must be easily accessible
at all times.
Weight without media
Single FH drive unit: 21,3 kg
Two FH drive unit: 24,3 kg
Two HH drive unit: 22,2 kg
Four HH drive unit 26,1 kg
Weight with media
(48 LTO cartridges)
Single FH drive unit: 30,6 kg
Two FH drive unit: 33,6 kg
Two HH drive unit: 31,4 kg
Four FH drive unit: 35,3 kg
Air quality
The Library should be placed in an area with minimal sources of
particulate contamination.
Avoid areas near frequently used doors and walkways, stacks of
supplies that collect dust, printers, and smoke-filled rooms.
Excessive dust and debris can damage tapes and tape drive.
Humidity
20-80 percent RH non-condensing
Clearance
Back: Minimum of 15.4 cm (6 inches)
Front: Minimum of 30.8 cm (12 inches)
– for mail slot
Minimum of 60 cm to remove magazines
Sides: Minimum of 5.08 cm (2 inches)
Table 4 Location requirements