![ACP ARX1 Service Manual Download Page 67](http://html.mh-extra.com/html/acp/arx1/arx1_service-manual_2840493067.webp)
©2018 ACP, Inc.
Cedar Rapids, IA 52404
Page 67 of 80
Part No. 16400033
Original Instructions
Temperature Sensor
Temperature Sensor
The Temperature Sensor (RTD) is a device whose electrical resistance changes with changes in temperature
Testing
With Connector Plug disconnected, test for resistance across the two (2) Wires
@ 70°F (23.9°C) ≈ 1100 Ω
@ 350°F (176.7°C) ≈ 1650 Ω
Removal and Replacement
1 Disconnect oven from Power Supply
2 Remove Top Panel (see Panel Removal)
3 Disconnect Connector Plug
4 Remove two (2) 11/32” (9mm) Hex Nuts securing
Temperature Sensor to top of oven
5 Pull Temperature Sensor up and out to remove
6 To replace, reverse these steps