Secondary, Monitor and Tertiary Interlock Switches
Secondary, Monitor and Tertiary Interlock Switches
The Secondary, Monitor and Tertiary Interlock Switches are part of a redundant safety system that will turnoff the
Microwave Circuit(s) when the door is opened in case of a Primary Switch failure
Testing
Use Test Plug on top of oven
Door Closed:
VT to BU = Open (Monitor)
VT to OR = Continuity (Secondary)
Note: Primary Switch MUST actuate first when opening door.
Removal and Replacement
1 Disconnect oven from Power Supply
For Secondary and Monitor Switches
2 Remove Top and Right Side Panels
(see Panel Removal)
3 Remove 11/32” (9mm) Hex Nut securing Switch Assembly
4
Lift Bracket off Mounting Stud and slide out.
5 Remove Wires noting their locations
6 Replace with Kit (P/N 59174580)
7 Reverse these steps to complete replacement
For Tertiary Switch
1 Remove Top and Right Side Panels
2 Remove two (2) Hex Head Screws securing Tertiary Switch
3 Remove Wires noting their locations
4 Reverse these steps to complete replacement