Measuring Procedure
1 Fill the glass beaker with 275 ml of cool water and place in
center of oven Close door
2 After oven has preheated, press the Blue Menu Icon
3 Press the
Manual Recipe
option
4 Enter
cooking time
by pressing the Time Entry Box
4-6
A number pad will appear Enter 30 seconds Cook Time
5 Press the “OK” Icon
6 Select desired
microwave power
by pressing Microwave Power
Entry Box Enter 100%
7 Select desired
fan speed
by pressing the Fan Speed Entry Box
Enter 0%
8 Press the Green Check Mark to begin
9 Move the Meter Probe at 1”/sec over all door/oven gaps
NOTE: Water must be changed every 30 seconds to prevent boiling. If
water boils the results may be inaccurate.
10 Make a note of any area that exceeds 4mW/cm2
11 Return the probe to any “spike areas” and allow it to remain for
17 seconds Make a note of the highest reading
12 When test is complete, open door and dispose of water