![ACP ARX1 Service Manual Download Page 64](http://html.mh-extra.com/html/acp/arx1/arx1_service-manual_2840493064.webp)
©2018 ACP, Inc.
Cedar Rapids, IA 52404
Page 64 of 80
Part No. 16400033
Original Instructions
Power Supply Board
Power Supply Board
The Power Supply Board steps down the incoming line voltage and rectifies it to 24 VDC for the electronics
of the oven
Testing
⚠
CAUTION
Extreme care must be taken when performing tests with line voltage applied.
With line voltage applied:
Voltage:
J1-1 (WH) to J1-3 (BK) = Line Voltage
J2-1 (RD) to J2-5 ≈ 24 VDC
J2-1 (RD) to J2-6 ≈ 24 VDC
J2-1 (RD) to J2-7 ≈ 24 VDC
Removal and Replacement
1 Disconnect oven from Power Supply
2 Remove Top and Right Side Panels (see Panel Removal)
3 Remove Wire Harnesses from Power Supply Board
4 Remove two (2) Screws securing Mounting Bracket
5 Disengage four (4) Retaining Clips securing Power
Supply Board
6 To replace, reverse these steps
⚠