![ACP ARX1 Service Manual Download Page 42](http://html.mh-extra.com/html/acp/arx1/arx1_service-manual_2840493042.webp)
©2018 ACP, Inc.
Cedar Rapids, IA 52404
Page 42 of 80
Part No. 16400033
Original Instructions
Oven Tests
All ACP Microwave Oven Power Outputs are rated using the IEC705 standards Using the IEC705 test method
requires precision measurements and equipment that is not practical to be performed in the field. Using the following
tests will indicate if the oven is performing satisfactorily
Power Test
Set Up:
• Oven MUST be at room temperature for accurate results
• Service Test Mode: Both Magnetrons
Equipment:
• 1000ml test container
• Thermometer
Procedure:
1 Fill the test container with cool tap water, as close to 60°F (16°C) as possible
2 Using the thermometer, stir the water for 10 seconds; measure and record the temperature
3 Place the container of water in the center of the oven and close the door
4 Heat the water on full power for 33 seconds
5 At the end of the cycle, remove the container from the oven
6 Once again, stir the water for 10 seconds, take another measurement and record
7 Subtract the starting water temperature from the ending water temperature to obtain the temperature rise
8 If the temperature rise meets or exceeds the nominal microwave energy output rating found on the oven’s
model/serial tag, the test is complete
9 If the temperature rise fails to meet the minimum, test the incoming line voltage to verify it is correct
10 Before retesting replace the water as in Step 1
Repeat Steps 2 – 7 If the temperature rise fails to meet the minimum, the oven needs to be serviced
ΔT
(°F)
Cooking
Output
Power (W)
ΔT
(°F)
Cooking
Output
Power (W)
ΔT
(°C)
Cooking
Output
Power (W)
ΔT
(°C)
Cooking
Output
Power (W)
10
1000
20
2000
5
1000
11
2000
11
1100
21
2100
55
1100
115
2100
12
1200
22
2200
65
1200
12
2200
14
1400
24
2400
75
1400
13
2400
17
1700
25
2500
95
1700
135
2500
18
1800
27
2700
10
1800
15
2700
19
1900
30
3000
105
1900
165
3000