Original Instructions
HV Capacitor
HV Capacitor
⚠
DANGER
The high voltages and currents at the filament and secondary winding of the transformer are extremely dangerous.
Never make any direct voltage or current measurements of this component. It is very dangerous to work near this
part when the oven is on, or if this circuitry has been switched off.
⚠
DANGER
All High Voltage Capacitors must be discharged before performing this procedure.
The HV Capacitor is used in the Microwave Circuit to provide the high voltage to supply the Magnetron
Depending on the model, there may be 1 or 2 HV Capacitors
Testing
Capacitance across the Terminals:
0.88μf ±3%
Continuity from each Terminal to the outer case: Open
Removal and Replacement
1 Disconnect oven from Power Supply
2 Remove Top, Right, Left and Rear Panels
(see Panel Removal)
3 Remove Wire from the device(s) noting their positions
4 Using a 1/4” Hex Socket, remove the four (4) Screws
securing the Mounting Crossbar
5 Remove the Screws securing the Capacitor(s) to the
Crossbar
6 To replace, reverse these steps
⚠
DANGER
⚠
DANGER