Troubleshooting Managed Volumes
Correcting Share-Import Errors
CLI Maintenance Guide
8-25
Correcting Share-Import Errors
After you enable a namespace volume, the volume reads all of its back-end shares and
imports
all of their files and directories. If anything goes wrong in any share, the
failed share shows a Status of “
Error
” in the
show namespace status
output, and one
of the errors in
Table 8-1
appears in the more-verbose
show namespace
output. Use
show namespace
(not
show namespace status
) to see the full error message.
Follow the suggestions in the table to find and fix the root cause of the error. Once the
error is corrected, retry the import.
The sections below the table describe various methods for either restarting the import
or removing the share.
Table 8-1. Share Status Conditions
Status Condition
Description/Action
Error: A directory was removed from
the filer during import.
A directory was found during an early scan of the filer share,
then later it was missing. Either a client or client application
must have accessed the filer directly (that is, not through this
managed volume) during the import.
This ARX cannot support unexpected changes to the back-end
shares during (or after) import.
Error: A filename/directory could not
be mapped to the namespace
character encoding.
One of the share’s directories has a name with Unicode
characters that are unsupported by the NFS
character-encoding
.
CIFS filenames are Unicode and can contain any character, but
NFS servers and clients must each configure their character
encoding for filenames. The volume cannot import a directory
with any un-mappable characters in its name.
You can use the
import rename-directories
unmapped-unicode
command to allow the volume to rename such directories during
import, or you can rename them manually at the filer. Then
restart the import.
Summary of Contents for Adaptive Resource Switch
Page 12: ...2 xii CLI Maintenance Guide...
Page 62: ...Backing Up the Running Configuration Restoring the Configuration 3 24 CLI Maintenance Guide...
Page 128: ...Metadata Utilities nsck and sync Clearing All nsck Jobs 5 48 CLI Maintenance Guide...
Page 206: ...Troubleshooting Network Connections Configuring Port Mirroring 7 32 CLI Maintenance Guide...
Page 306: ...GUI Maintenance Restarting the GUI 10 4 CLI Maintenance Guide...
Page 316: ...Powering Down the ARX Restoring Power 11 10 CLI Maintenance Guide...
Page 318: ...Copyright 2 CLI Maintenance Guide...
Page 324: ...Index 6 CLI Maintenance Guide...