ProPanel Classic
Page 15 of 44
Fundamental Readout Functions
Auto on/off
To prolong battery life, the Readout has a built-in function that turns off the
Readout after a period of no movement or key activity. The Auto On/Off
function is programmable from 0 (always on), to 240 (minutes) before entering
sleep mode.
Press the
ON
/
OFF
key or move the ProPanel to wake up the Readout. Any
key press or system motion while the Readout is awake restarts the Auto
On/Off timer.
Use
Programming Parameter (Pr12)
to set this interval.
Reading Direction
If the direction of readings, (increasing vs. decreasing) is opposite the desired
direction, use
to reverse the Reading Direction.
THIS PARAMETER HAS BEEN FACTORY SET FOR PROPANEL
Resolution
Four selectable display resolutions are available.
Fractional inches display mode is not affected by resolution changes.
.1in
.1mm
.1cm
or
.01in
.01mm
.01cm
or
.001in
.01mm
.001cm
or
.0005in
.01mm
.001cm
Use
Programming Parameter (Pr4)
to set the displayed resolution.
Data displayed (and sent to the SPC output) is auto-ranging. This means the
selected resolution may be temporarily overridden if the measurement or
position to be displayed exceeds the maximum displayable value for the
programmed resolution. The Readout will continue to automatically reduce
the resolution to 1 decimal place or until an allowable resolution is achieved.
The available resolutions are:
Inch Resolution
Maximum Value (Inches)
4 decimal places
99.9999
3 decimal places
999.999
2 decimal places
9999.99
1 decimal place
99999.9
Millimeter Resolution
Maximum Value (mm)
2 decimal places
9999.99
1 decimal place
99999.9