Hold
The Readout provides a feature that allows the displayed
measurement to be “frozen” in time while the Jaw is moved from
its current position. This allows measurements to be captured on
the Readout and held for later viewing regardless of the current
Jaw position. To activate the Hold Mode, momentarily press the
F4
key.
HOLD
will be displayed in the upper left corner of the
LCD. The currently displayed measurement and selected key
presses will be frozen at this point. To release the HOLD feature,
momentarily press the
F4
key again, or cycle power.
NOTES:
If power is cycled when Hold Mode is active, any key (such as
UNITS
,
DATUM
,
+
or
–)
that was depressed while in Hold Mode will
be executed when power is restored.
Leaving the normal measurement mode, (i.e. enter programming
mode, SEND, or using the Go/No Go editor) causes the Readout
to automatically exit HOLD
Delete
Momentarily
pressing
F2
sends a special “
delete
” signal to the
output data port. When a ProRF Transmitter is attached to this
port, a “
delete
” message will be sent to the ProRF Receiver. This
“
delete
” message removes the last measurement from a cut list
when connected to another device such as an automated stop or cutting
system.