PROFIBUS-DP, the format of function code 10H is defined as follows:
Query
Frame Bytes
Caption
Byte1
FAH
Byte2
10H
Byte3
starting address high byte
Byte4
starting address low byte
Byte5
quantity of registers high byte
Byte6
quantity of registers low byte
Byte7
byte count
Byte8
register value 1 high byte
Byte9
register value 1 low byte
Byte10
register value 2 high byte
Byte11
register value 2 low byte
......
......
Byte32
0
“Quantity of registers” indicates how many words will be written.
“Byte count” indicates how many bytes will be written. If “quantity of register” is N,
then “byte count” is (N×2).
It is important to note: the response has a 16-word frame, so the maximum
"quantiy of registers" should be less than 13. Otherwise it will return an error
result.
Response
The normal response returns the function code, starting address, and quantity
of registers written.
Shop for Power Metering products online at:
1.877.766.5412
www.
PowerMeterStore
.com
Summary of Contents for Acuvim II
Page 2: ...Shop for Power Metering products online at 1 877 766 5412 www PowerMeterStore com...
Page 8: ...VI Shop for Power Metering products online at 1 877 766 5412 www PowerMeterStore com...
Page 16: ...8 Shop for Power Metering products online at 1 877 766 5412 www PowerMeterStore com...
Page 55: ...47 Shop for Power Metering products online at 1 877 766 5412 www PowerMeterStore com...
Page 60: ...52 Shop for Power Metering products online at 1 877 766 5412 www PowerMeterStore com...
Page 167: ...159 Fig 5 46 Shop for Power Metering products online at 1 877 766 5412 www PowerMeterStore com...
Page 268: ...260 Shop for Power Metering products online at 1 877 766 5412 www PowerMeterStore com...