Standard Owner’s Booklet

BLOOD GLUCOSE METER

ACCU-CHEK, ACCU-CHEK AVIVA, ACCU-CHEK AVIVA COMBO, and ACCU-CHEK SPIRIT COMBO  
are trademarks of Roche.
The 

Bluetooth

®

 word mark and logos are registered trademarks owned by Bluetooth SIG, Inc.  

and any use of such marks by Roche is under license. All other product names and trademarks 
are the property of their respective owners.

Roche Diabetes Care GmbH
Sandhofer Strasse 116
68305 Mannheim, Germany
www.accu-chek.com

53895_00048010161_E.indb   1

9/4/15   9:34 AM

Summary of Contents for Aviva

Page 1: ...15 2015 Roche Diabetes Care Manufactured in USA Distributed by Roche Diagnostics Canada 201 Armand Frappier Blvd Laval Quebec Canada H7V 4A2 Standard Owner s Booklet BLOOD GLUCOSE METER ACCU CHEK ACCU...

Page 2: ...LAST UPDATE 2015 08 Canada Accu Chek Pump Support 1 800 688 4578 toll free www accu chek ca 53895_00048010161_E indb 2 9 4 15 9 34 AM...

Page 3: ...dispose of used test strips and lancets Home use of the Accu Chek Aviva Combo System is limited to capillary whole blood testing About Your New Meter The meter is designed and can be used for testing...

Page 4: ...o a healthcare professional Run a control test when you open a new box of test strips or if you think that your test result is incorrect Running a control test lets you know that the meter and test st...

Page 5: ...ssional s instructions or call your healthcare professional Special Information to Consider When Using This Meter Do not use this device to measure blood glucose if you or a person to whom you are pro...

Page 6: ...iv 53895_00048010161_E indb 4 9 4 15 9 34 AM...

Page 7: ...he Accu Chek Aviva Combo Meter at a Glance 17 1 3 The Accu Chek Spirit Combo Insulin Pump at a Glance 25 1 4 Summary of Features 27 1 5 Screen Content and Navigation 37 2 Testing Your Blood Glucose 47...

Page 8: ...ng 71 3 1 Overview 72 3 2 Why Perform Control Tests 73 3 3 About the Control Solutions 74 3 4 Performing a Control Test 75 3 5 Understanding Control Test Results 81 4 Managing Your Data 87 4 1 Overvie...

Page 9: ...ime Blocks Health Events Advice Options Bolus Advice Set Up 175 5 7 Setting Warning Limits Hyper Hypo 184 5 8 Turning Key Lock On or Off 187 5 9 Setting the Language 190 5 10 Setting Units Carbs 193 5...

Page 10: ...s 220 6 5 List of Warnings 228 6 6 List of Errors 234 7 Care and Maintenance 237 7 1 Overview 238 7 2 Changing the Batteries 239 7 3 Power Saving Tips 242 7 4 Cleaning the Meter 243 7 5 Maintenance an...

Page 11: ...Meter Strips Lancets and Batteries 271 9 6 Warranty 272 9 7 Additional Supplies 274 9 8 Information for Healthcare Professionals 275 Appendices 277 Appendix A Abbreviations 277 Appendix B Carb Units...

Page 12: ...6 53895_00048010161_E indb 6 9 4 15 9 34 AM...

Page 13: ...elp Just call Accu Chek Customer Care at 1 800 688 4578 You can also visit www accu chek ca for diabetes management tools Introduction Whether the Accu Chek Aviva Combo meter is your first blood gluco...

Page 14: ...Chek Aviva Combo system Testing your blood glucose Control testing Managing your data Changing the meter settings Understanding the icons reminders warnings and errors Care and maintenance Troublesho...

Page 15: ...Bolus advice Daily time blocks that can be adjusted to fit your lifestyle Data management Data transfer Date reminders bG test reminders Alarm Clock Target bG levels and Health Events An electronic di...

Page 16: ...10 i NOTE Blood glucose and bG are interchangeable and mean the same thing 53895_00048010161_E indb 10 9 4 15 9 34 AM...

Page 17: ...site The Accu Chek Aviva Combo meter can also be used to interface with and remotely control compatible Accu Chek insulin infusion pumps via Bluetooth wireless technology radio frequency communicatio...

Page 18: ...e Clinical and Laboratory Standards Institute Protection of Laboratory Workers from Occupationally Acquired Infections Approved Guideline Third Edition CLSI document M29 A3 2005 Choking hazard Small p...

Page 19: ...gned for testing fresh whole blood samples for example blood from your fingertip The meter is for outside the body in vitro use It should not be used to diagnose diabetes This meter requires Accu Chek...

Page 20: ...14 53895_00048010161_E indb 14 9 4 15 9 34 AM...

Page 21: ...m 1 1 Overview 16 1 2 The Accu Chek Aviva Combo Meter at a Glance 17 1 3 The Accu Chek Spirit Combo Insulin Pump at a Glance 25 1 4 Summary of Features 27 1 5 Screen Content and Navigation 37 53895_00...

Page 22: ...ens in this booklet may look slightly different from the screens on the meter If you have any questions about the meter screens contact Accu Chek Customer Care at 1 800 688 4578 On the meter display t...

Page 23: ...ht Soft Keys Press to select the menu or option above the key 3 Buttons Press to enter menus or the diary adjust settings and scroll through results 4 Backlight Button Press to adjust the backlight le...

Page 24: ...fers data from the meter to a computer 8 Activation Chip Slot Activation chip is pre inserted here 9 Battery Door Remove the battery door by pushing the tab and pulling up the door 7 9 8 53895_0004801...

Page 25: ...compartment 11 Control Solution Bottle for example 12 Test Strip Container for example 13 Test Strip Insert this end of the test strip into the meter 14 Test Strip Yellow Window Touch blood drop or c...

Page 26: ...ter is already coded and comes with a pre inserted black activation chip that you never need to change Even if you use test strips from boxes that contain another activation chip that is a different c...

Page 27: ...y 7 Right Arrow 8 Enter 9 Backlight i NOTE You hear a sound every time an active button soft key is pressed unless you turned off the key sound Press or insert a test strip to turn on the meter If the...

Page 28: ...en Right Arrow Move or scroll to the right in a screen Up Arrow Move or scroll up in a screen Down Arrow Move or scroll down in a screen Left Soft Key Select the option above the key on the display Ri...

Page 29: ...ave changes and exit the entry field Backlight Adjust the backlight level low medium high Turn Bluetooth wireless technology on and off press and hold in the BLUETOOTH screen Power On Off Turn the met...

Page 30: ...ction When the buttons are locked press and hold and until the Main Menu appears Unlock Keys Unlock the buttons With the meter turned off press and hold and then press Meter Pump Pairing Begin meter a...

Page 31: ...s and information screens 2 OK Key Selects current settings displayed on screen saves changes exits a screen and allows the user to view the QUICK INFO screen 3 Display Shows menus messages and data s...

Page 32: ...Bolus and turns off the STOP Warning 7 Down Key Moves backward in an information screen decreases a setting programs a Quick Bolus cancels a Quick Bolus and turns off the STOP Warning 8 Infusion Set C...

Page 33: ...ressing and releasing the backlight button The backlight adjusts from low to medium to high and back to low again If set to the medium or high level and the buttons are not pressed for about 15 second...

Page 34: ...r more information see Chapter 6 Icons Reminders Warnings and Errors Blood Glucose Test Your new meter allows you to enter detailed information for each blood glucose test to include Meal time Pre Mea...

Page 35: ...s adapted to the time of day and your changing situations This function is activated only if you set up bolus advice on the meter For instructions on how to set up bolus advice see Chapter 5 Changing...

Page 36: ...ology is activated The meter must be paired with the pump For more information see the Advanced Owner s Booklet Administering a Bolus Using your new meter you can deliver a bolus Remotely on your pump...

Page 37: ...standard week and target tables and graphs of the data in the diary You can view the data in graph or table format for the last 7 14 30 60 or 90 days For more information see Chapter 4 Managing Your D...

Page 38: ...re information see Chapter 5 Changing Meter Settings Time Blocks Time blocks allow you to divide a day into different time periods Setting time blocks to fit your own schedule helps you and your healt...

Page 39: ...he following when setting up time blocks Determine the appropriate time range by reviewing the end time for each time block Review the acceptable blood glucose target range low and high for each time...

Page 40: ...asting if you set up bolus advice Fasting does not scale bolus advice calculations and is not adjustable Health events available on the meter are Exercise 1 Exercise 2 Stress Illness Premenstrual Fast...

Page 41: ...mmol L and with a reminder time of 60 minutes You have a blood glucose result higher than 13 3 mmol L perhaps 15 0 mmol L In 60 minutes the meter reminds you to perform another blood glucose test The...

Page 42: ...for Other for any other daily reminder You can set up to eight reminders per day For more information see Chapter 5 Changing Meter Settings Date Reminders The meter can be set up to remind you of upc...

Page 43: ...ction provides an explanation of how to understand and navigate the screens on the meter Each time the meter is turned on this splash screen Accu Chek logo screen is displayed for a short period of ti...

Page 44: ...te is turned on 4 Date 5 Low Battery Icon Appears when the meter batteries are low 6 Menu Options 7 Bluetooth Wireless Technology Icon Indicates whether the Bluetooth wireless technology is on off or...

Page 45: ...or to highlight blue the menu item and then press When using the meter to remotely control the pump the buttons of the meter have differing functions For more information see the Advanced Owner s Book...

Page 46: ...e using the meter Icon Communication State Bluetooth wireless technology is on The meter and pump are communicating Bluetooth wireless technology is off The meter and pump are not communicating Blueto...

Page 47: ...41 1 Connecting to the Pump screen during pairing This screen appears when Bluetooth wireless technology is on and the meter is connecting to the pump 53895_00048010161_E indb 41 9 4 15 9 34 AM...

Page 48: ...e screen 4 Secondary Title Bar When necessary a secondary title bar appears Secondary menu text is displayed here 5 Scroll Bar If there is more information available than fits on the screen a vertical...

Page 49: ...t be selected it appears as a pop up menu To open a pop up menu or entry field press Press or to select the appropriate pop up menu option or until the correct numerical entry is present and then pres...

Page 50: ...eral Navigation Steps To change the settings or enter information into the meter 1 Press or to select a menu option and press Repeat the previous step as necessary 53895_00048010161_E indb 44 9 4 15 9...

Page 51: ...changes and return to the previous screen Press or or or to select an option or a desired entry field and press 2 Press or to select the desired entry and press Repeat Steps 2 and 3 as necessary 3 538...

Page 52: ...46 53895_00048010161_E indb 46 9 4 15 9 34 AM...

Page 53: ...ek Aviva Combo System 49 2 3 Performing a Blood Glucose Test 51 2 4 Detailed Blood Glucose Results 58 2 5 Understanding Blood Glucose Results 62 2 6 Unusual Blood Glucose Results 67 2 7 Symptoms of Hi...

Page 54: ...to understand how to perform a blood glucose test properly You can perform a blood glucose test from your fingertip i NOTE Blood glucose and bG are interchangeable and mean the same thing 53895_00048...

Page 55: ...Do not use the test strips after the use by date If the use by date is missing or cannot be read do not use the test strips Do not refrigerate freeze or expose strips to heat moisture or humidity Tem...

Page 56: ...ore test strips in extreme temperatures or moisture areas bathroom kitchen laundry room car or garage Heat and moisture can damage your test strips Do not bend cut or alter the test strips Do not get...

Page 57: ...serted activation chip a test strip a lancing device and a lancet wWARNING Do not change your treatment because of one blood glucose result NEVER ignore symptoms of high or low blood glucose i NOTE If...

Page 58: ...t Performing a Fingertip Blood Glucose Test Prepare Check the Use By Date Insert Test Strip Test Blood Sample bG Result Insert the test strip into the meter in the direction of the arrow The meter tur...

Page 59: ...rs The test strip is ready for testing Fingerstick Perform a fingerstick with the lancing device Fingerstick Gently squeeze your finger to assist the flow of blood This helps you get a blood drop 5389...

Page 60: ...nt edge of the yellow window of the test strip Do not put blood on top of the test strip 6 When the test strip has enough blood the Analyzing screen appears The result appears on the display 53895_000...

Page 61: ...55 2 7 Approximately 3 seconds later the detailed bG Result screen appears Remove and discard the used test strip 53895_00048010161_E indb 55 9 4 15 9 34 AM...

Page 62: ...or occurs remove and discard the used test strip and repeat the test with a new test strip Be careful not to put any fluids into the test strip slot The meter cannot be turned off when the following s...

Page 63: ...con is displayed insert a test strip into the meter From the Main Menu select Bolus Advice and press If bG Test is displayed instead of an actual blood glucose value then you can start a blood glucose...

Page 64: ...g information 1 Test Time 2 Meal Time 3 Carbohydrates 4 Health Event 5 Active Insulin Displayed only if bolus advice is activated and data has recently been read from the pump 6 Status Bar 7 Blood Glu...

Page 65: ...etailed bG Results Change Meal Time Carbs Health Events Optional The detailed bG Result screen allows you to view and to add information to a blood glucose result 53895_00048010161_E indb 59 9 4 15 9...

Page 66: ...calculated amount of Active Insulin To save the changes and exit the detailed bG Result screen To return to the Main Menu press To proceed to the Bolus Advice screen press How to Add Information to a...

Page 67: ...fully used Active insulin appears only if bolus advice is activated Calculation of the amount of the active insulin is completed automatically by the meter If necessary the meter rounds the active in...

Page 68: ...4 Status Bar 5 Unit of Measure i NOTE If the dosed test strip is removed from the meter before results or errors are displayed a blood glucose result will not appear After approximately 3 seconds the...

Page 69: ...e status bar descriptions with sample displays Green indicates the result is within the target range for the current time block Yellow indicates the result is below the target range for the current ti...

Page 70: ...result is above the target range for the current time block The result is not above the hyper warning limit Light blue with Hyper indicates the result is above the hyper warning limit 53895_000480101...

Page 71: ...d the test result may be below the measurement range Contact your healthcare professional If HI is displayed the test result may be above the measurement range Contact your healthcare professional 538...

Page 72: ...se results are outside the hyper or hypo warning limits or outside the measurement range of the meter then the warning is displayed after the bG Result screen Select OK to acknowledge the warning and...

Page 73: ...test strip container Repeat the blood glucose test with a new test strip 4 Were the test strips stored in a cool dry place Repeat the blood glucose test with a properly stored test strip 5 Did you fol...

Page 74: ...glycemia anxiety shakiness sweating headache increased hunger dizziness pale skin color sudden change in mood or irritability fatigue difficulty concentrating clumsiness palpitations and or confusion...

Page 75: ...st be fasting Take your meter to the healthcare professional s office and test yourself by fingerstick within five minutes of having blood drawn from your arm by a healthcare professional Keep in mind...

Page 76: ...70 53895_00048010161_E indb 70 9 4 15 9 34 AM...

Page 77: ...l Testing 3 1 Overview 72 3 2 Why Perform Control Tests 73 3 3 About the Control Solutions 74 3 4 Performing a Control Test 75 3 5 Understanding Control Test Results 81 53895_00048010161_E indb 71 9 4...

Page 78: ...st to ensure the accuracy of your blood glucose meter It is recommended you complete a control test prior to performing a blood glucose test for the first time i NOTE Blood glucose and bG are intercha...

Page 79: ...a control test when You open a new test strip box You left the test strip container open You want to check the meter and test strips Your test strips were stored in extreme temperatures humidity or bo...

Page 80: ...date you opened the control solution bottle on the bottle label The solution is good for 3 months from that date or until the use by date on the bottle label whichever comes first Do not use control s...

Page 81: ...solution Level 1 Level 2 or both The control level is printed on the bottle label 1 Test Time 2 Control Result 3 Test Date 4 Unit of Measure 3 4 Performing a Control Test The Control Result screen di...

Page 82: ...ck the use by date on the test strip container Do not use test strips past the use by date Insert the test strip into the meter in the direction of the arrow The meter turns on The Apply Sample screen...

Page 83: ...on a flat surface like a table Select the control solution to test You will enter the level later in the test 5 Remove the control bottle cap Wipe the tip of the bottle with a tissue 53895_00048010161...

Page 84: ...tle tightly 8 The control result appears on the display Select Level to display the control solution level pop up menu 6 Squeeze the bottle until a tiny drop forms at the tip Touch the drop to the fro...

Page 85: ...vel and press 10 Remove and discard the test strip For information on understanding control test results proceed to the next section or press to save this result and display the Main Menu screen 53895...

Page 86: ...along with No Entry and then the detailed Control Result screen is displayed When the Control Level screen is displayed and you turn off the meter or if the meter auto powers off without selecting a c...

Page 87: ...sult and display Main Menu screen 5 Test Date 6 Control Solution Level 7 Result Within range or Out of range 3 5 Understanding Control Test Results The detailed Control Result screen displays the foll...

Page 88: ...evel selected the meter displays whether the result is within or outside of the acceptable range When the control test result is inside the range on the test strip container the test strips and the me...

Page 89: ...ange Out of range appears on the detailed Control Result screen If HI is displayed the control test result may be above the measurement range If LO is displayed the control test result may be below th...

Page 90: ...84 If the meter stored No Entry for the control solution level then appears with no indication of in or out of range 53895_00048010161_E indb 84 9 4 15 9 34 AM...

Page 91: ...ith a new test strip and a fresh drop of control solution 3 Were the caps on the test strip container and the control solution bottle always closed tightly Replace the test strips or control solutions...

Page 92: ...hen you performed the control test If you chose the wrong control solution level you can still compare the control result to the range printed on the test strip container 8 Are you still unsure of the...

Page 93: ...aging Your Data 4 1 Overview 88 4 2 Viewing or Modifying Your Data 92 4 3 Adding New Data 101 4 4 Reporting Your Data 104 4 5 Downloading Your Data to a Computer 144 53895_00048010161_E indb 87 9 4 15...

Page 94: ...e g meal time carbs health event and bolus In addition for a specific diary record you are able to change or add to its attributes The meter generates reports such as blood glucose averages with stan...

Page 95: ...You must be the only user of the meter because the diary data will be incorrect if the meter is shared Blood glucose and bG are interchangeable and mean the same thing 53895_00048010161_E indb 89 9 4...

Page 96: ...he newest to the oldest It is very important to have the correct time and date set Having the correct time and date setting helps ensure accurate interpretation of blood glucose results by you and you...

Page 97: ...replace the batteries For more information on changing the batteries see Chapter 7 Care and Maintenance Once 1 000 records are in the diary memory adding a new record causes the oldest diary record to...

Page 98: ...Time of Blood Glucose Test 3 Blood Glucose Test Icon 4 Meal Time Icon 5 Unit of Measure 6 Blood Glucose Result 7 Health Event Icon 8 Carbs Icon 9 Appropriate Bolus Icon 10 Select View Change meter di...

Page 99: ...ch they occurred with the most recent record shown on top For the blood glucose result HI is displayed if the test result is above the measurement range LO is displayed if the test result is below the...

Page 100: ...formation exists for this diary record regarding carbs Health Event Icon is displayed when information exists for this diary record regarding health events Standard Bolus Not Confirmed Delivery has no...

Page 101: ...med Delivery has not been confirmed by the pump Extended Bolus Confirmed Delivery has been confirmed by the pump Manual Pump Delivery has not been confirmed by the pump Pen Syringe Bolus Pump does not...

Page 102: ...rd with its attributes blood glucose value meal time carbs health event and bolus Main Menu My Data View Data 1 From the Main Menu select My Data and press 2 Select View Data and press 53895_000480101...

Page 103: ...blood glucose bolus or carbs To choose another view press a pop up menu appears Select the view you want and press Press or to view other records the screen scrolls if there are additional records To...

Page 104: ...o view the previous record or press to view the next newer record To return to the previous screen press or To modify a diary record press and continue to the next step 53895_00048010161_E indb 98 9 4...

Page 105: ...ew Detail screen press 5 Select the entry field to modify and press Make the change in the entry field and press Modify other fields as needed To save the changes and return to the View Detail screen...

Page 106: ...ed if the Bolus Bolus type is confirmed standard extended or multiwave Bolus Blood glucose result was below the hypo warning limit Meal Time Record has no blood glucose value Meal Time Carbs Health Ev...

Page 107: ...nd bolus The Add Data screen displays the following information 1 Time Entry Field 2 Date Entry Field 3 Carbs Entry Field 4 Health Entry Field 5 Bolus Entry Field 6 Save Appears once data has been ent...

Page 108: ...and press 2 3 Select Add Data and press Select an entry field and press Make addition in the entry field and press Make additions to other entry fields as needed To save the changes and return to the...

Page 109: ...adding a diary record although the date and time cannot be set in the future Before a diary record can be saved data must be entered not including date and time Save is not displayed above until data...

Page 110: ...mes 3 Blood Glucose Standard Deviation Calculated for the time range 4 Number of Tests Used to calculate the averages and standard deviations 5 Blood Glucose Average Calculated for the time range 4 1...

Page 111: ...round the blood glucose average A low standard deviation means the blood glucose results are tightly clustered around the blood glucose average a high standard deviation means the blood glucose result...

Page 112: ...cose averages and standard deviations for the time range you choose 7 14 30 60 or 90 days Main Menu My Data Reports bG Averages 1 From the Main Menu select My Data and press 2 3 Select Reports and pre...

Page 113: ...ed To display blood glucose averages for another time range last 7 14 30 60 or 90 days press either or to scroll the screen until you reach the time range you need To return to the Reports screen pres...

Page 114: ...cose record trends for the time range you choose last 8 hours 24 hours 48 hours or 7 days Main Menu My Data Reports Trend 1 From the Main Menu select My Data and press 2 Select Reports and press 3 Sel...

Page 115: ...e Unit of Measure 4 Blood Glucose Icon 5 Times or Days of Month 6 Bolus Icon 7 Bolus Unit of Measure 8 Maximum Bolus Amount Indicator 9 Maximum Carbs Amount Indicator 10 Carbs Unit of Measure 11 Carbs...

Page 116: ...insulin amount 14 Each Blood Glucose Value Connected with lines 15 Carb Value Dark orange bar height shown is in relation to the carbs amount 16 Warning Limit Hypo Level Red horizontal line 17 Time Ch...

Page 117: ...irectly on the pump go to My Data on the meter to receive the bolus information automatically Do this before your next blood glucose test Replace the batteries when the Low Battery icon appears This m...

Page 118: ...ttom of the Trend Graph screen the time and date of one or more data points in the trend graph may not match the time stamp in My Data because the meter clock has been changed All times in the trend g...

Page 119: ...U On the right side of the graph the Maximum Carbs Amount Indicator is a horizontal line with the corresponding value shown below it The purpose of this indicator is to scale the bottom portion of the...

Page 120: ...h for another meal time selection Overall Pre Meal Post Meal Bedtime or Other press either or to highlight the meal time selection field immediately below the time range which is at the top of the scr...

Page 121: ...115 4 i NOTE The meter saves the current settings time range meal time and graph view when you select Back or when the meter powers off 53895_00048010161_E indb 115 9 4 15 9 34 AM...

Page 122: ...ds 4 Blood Glucose Icon with Blood Glucose Unit of Measure 5 Time Change Icon Only shown when meter time has been changed for this data 6 Carbs Icon with Carbs Unit of Measure 7 Bolus Icon with Bolus...

Page 123: ...cause the meter clock has been changed All times in the trend table show the data relative to the current meter time For example 1 You take a bG test and the value is stored in the meter at 9 00 2 The...

Page 124: ...f screen Press either or until you reach the time range you need 3 To display a trend table for another meal time selection Overall Pre Meal Post Meal Bedtime or Other press either or to highlight the...

Page 125: ...ous section for more information To return to the Reports screen press i NOTE The meter saves the current settings time range meal time and table view when you select Back or when the meter powers off...

Page 126: ...tests and standard deviations within predetermined time blocks for the time range you choose last 7 14 30 60 or 90 days Main Menu My Data Reports Standard Day 1 From the Main Menu select My Data and p...

Page 127: ...glucose test results for the selected criteria The top of the box indicates 1 standard deviation above the average and the bottom of the box indicates 1 standard deviation below the average The box is...

Page 128: ...available to display the standard day graph the No Data Available screen is displayed The standard day graph does not include corrupt results control results HI values or LO values 53895_00048010161_...

Page 129: ...or another meal time selection Overall Pre Meal Post Meal Bedtime or Other press either or to highlight the meal time selection field immediately below the time range which is at the top of the screen...

Page 130: ...124 i NOTE The meter saves the current settings time range meal time and graph view when you select Back or when the meter powers off 53895_00048010161_E indb 124 9 4 15 9 34 AM...

Page 131: ...25 4 Standard Day Table Screen 1 Time Range 2 Meal Time Selection 3 Time Block 4 Blood Glucose Average 5 Standard Deviation SD 6 Number of Tests 1 2 3 4 5 6 53895_00048010161_E indb 125 9 4 15 9 34 AM...

Page 132: ...reen is displayed Standard day table calculations do not include corrupt results control results or HI and LO results For a standard deviation to be displayed for a given time block there must have be...

Page 133: ...il you reach the time range you need 3 To display a standard day table for another meal time selection Overall Pre Meal Post Meal Bedtime or Other press either or to highlight the meal time selection...

Page 134: ...us section for more information To return to the Reports screen press i NOTE The meter saves the current settings time range meal time and table view when you select Back or when the meter powers off...

Page 135: ...r of tests and standard deviations for each day of the week for the time range you choose last 7 14 30 60 or 90 days Main Menu My Data Reports Standard Week 1 From the Main Menu select My Data and pre...

Page 136: ...results for the selected criteria The top of the box indicates 1 standard deviation above the average and the bottom of the box indicates 1 standard deviation below the average The box is not displaye...

Page 137: ...available to display the standard week graph the No Data Available screen is displayed The standard week graph does not include corrupt results control results HI values or LO values 53895_0004801016...

Page 138: ...or another meal time selection Overall Pre Meal Post Meal Bedtime or Other press either or to highlight the meal time selection field immediately below the time range which is at the top of the screen...

Page 139: ...133 4 i NOTE The meter saves the current settings time range meal time and graph view when you select Back or when the meter powers off 53895_00048010161_E indb 133 9 4 15 9 34 AM...

Page 140: ...ilable to display the standard week table the No Data Available screen is displayed Standard week table calculations do not include corrupt results control results or HI and LO results For a standard...

Page 141: ...reach the time range you need 3 To display a standard week table for another meal time selection Overall Pre Meal Post Meal Bedtime or Other press either or to highlight the meal time selection field...

Page 142: ...us section for more information To return to the Reports screen press i NOTE The meter saves the current settings time range meal time and table view when you select Back or when the meter powers off...

Page 143: ...d glucose records as Above Within Below and Hypo for the time range you choose last 7 14 30 60 or 90 days Main Menu My Data Reports Target 1 From the Main Menu select My Data and press 2 Select Report...

Page 144: ...t Represents the percentages for the blood glucose result categories i NOTE If data are not available to display the target graph the No Data Available screen is displayed The target graph does not in...

Page 145: ...r meal time selection Overall Pre Meal Post Meal Bedtime or Other press either or to highlight the meal time selection field immediately below the time range which is at the top of the screen Press ei...

Page 146: ...140 i NOTE The meter saves the current settings time range meal time and graph view when you select Back or when the meter powers off 53895_00048010161_E indb 140 9 4 15 9 34 AM...

Page 147: ...ion 4 Percentage of Occurrence i NOTE If results or data are not available for the selected time period and meal time the No Data Available screen is displayed The target table does not include corrup...

Page 148: ...meal time selection Overall Pre Meal Post Meal Bedtime or Other press either or to highlight the meal time selection field immediately below the time range which is at the top of the screen Press eit...

Page 149: ...143 4 i NOTE The meter saves the current settings time range meal time and table view when you select Back or when the meter powers off 53895_00048010161_E indb 143 9 4 15 9 34 AM...

Page 150: ...l the software according to the instructions Connect the computer cable according to the instructions 2 Run the software program and follow the instructions about how to download information Ensure th...

Page 151: ...IR window on the top of the meter Locate the IR window on the computer s infrared cable Point the two IR windows toward each other They should be 3 to 10 cm apart 6 Follow the prompts on your computer...

Page 152: ...displayed for 3 seconds and then the meter turns off i NOTE If the data did not transfer successfully turn off the meter turn the meter back on and try again If you still have problems contact Accu Ch...

Page 153: ...5 Setting Bolus Advice for the First Time 165 5 6 Setting Time Blocks Health Events Advice Options Bolus Advice Set Up 175 5 7 Setting Warning Limits Hyper Hypo 184 5 8 Turning Key Lock On or Off 187...

Page 154: ...148 5 14 Setting the Time Format Time Date 202 5 15 Setting Time Blocks Bolus Advice Not Set Up 205 5 16 Backlight Settings 213 53895_00048010161_E indb 148 9 4 15 9 34 AM...

Page 155: ...elected Settings Important Information When editing a setting any unsaved changes are discarded if the meter turns off or if a test strip is inserted into the meter It is important to ensure that the...

Page 156: ...chedule snooze the reminder by pressing The snooze time for After High bG is 15 minutes The snooze time for After Low bG and After Meal is 5 minutes If not dismissed or snoozed the reminder is display...

Page 157: ...Main Menu Settings Reminders bG Test Reminders 1 From the Main Menu select Settings and press 2 3 Select Reminders and press Select bG Test Reminders and press 53895_00048010161_E indb 151 9 4 15 9 3...

Page 158: ...or Off and press To Change the bG Threshold Select the bG Threshold entry field and press Set the bG Threshold level and press To Change the Remind After Time Select the Remind After entry field and...

Page 159: ...the Reminder entry field and press Select On or Off and press To Change the Snack Size Select the Snack Size entry field and press Set the Snack Size amount and press To Change the Remind After Time...

Page 160: ...snack size you want to be reminded to retest your blood glucose and press To save the changes press If you did not change the Snack Size the meter returns to the bG Test Reminders screen If you chang...

Page 161: ...ter Meal screen for the first time if bolus advice has not been set up the default for Snack Size is no entry g If bolus advice has been set up the default value is the value set for the Snack Size on...

Page 162: ...he reminder is displayed when the meter powers down Alarm Clock bG Test Dismiss the reminder by pressing Reschedule snooze the reminder for 15 minutes by pressing Alarm Clock Other Dismiss the reminde...

Page 163: ...157 5 Main Menu Settings Reminders Alarm Clock 1 From the Main Menu select Settings and press 2 Select Reminders and press 3 Select Alarm Clock and press 53895_00048010161_E indb 157 9 4 15 9 34 AM...

Page 164: ...inder i e bG Test or Other and press Repeat the above steps to set additional reminders 4 To Turn Off a Reminder Select the type of Reminder entry field i e bG Test or Other and press Select Off and p...

Page 165: ...t in 15 minute increments where HH is hour MM is minutes and with am or pm for the 12 hour format If you tested within 30 minutes of a bG Test Reminder the reminder does not occur Exposure to extreme...

Page 166: ...ng reminder for an infusion set change for the interval you choose 1 day 2 days or 3 days Date Reminders Important Information Displayed when you turn on the meter and a test strip has not been insert...

Page 167: ...1 5 Main Menu Settings Reminders Date Reminders 1 From the Main Menu select Settings and press 2 3 Select Reminders and press Select Date Reminders and press 53895_00048010161_E indb 161 9 4 15 9 34 A...

Page 168: ...lect the Reminder entry field and press Select On or Off and press To Set the Date Select the Date entry field and press Set the Day and press Set the Month and press Set the Year and press To Set the...

Page 169: ...save the changes and return to the Date Reminders screen press To Set the Date Select the Date entry field and press Set the Day and press Set the Month and press Set the Year and press To Set the Ti...

Page 170: ...ate Reminder is optional If you choose not to set a time ensure the Time entry field value is no entry To cancel changes or to return to the Date Reminders screen press Time for the Dr Visit Reminder...

Page 171: ...n the Getting Started Guide before continuing Prior to setting up time blocks for bolus advice it is recommended that you decide how many time blocks you need and also determine the start end times Ta...

Page 172: ...s 4 Time Block End Time 5 Target Range Upper Limit Value 6 Carb Ratio Number of Carbs 7 Insulin Sensitivity Number of Insulin Units 8 Scroll Bar 9 Insulin Sensitivity Change in Glucose Level Time Bloc...

Page 173: ...e Main Menu select Settings and press If you do NOT want to set up bolus advice press to return to the Settings screen To set up bolus advice press and continue to the next step Select Bolus Advice an...

Page 174: ...press 5 To Change Time Blocks Select a time block to edit and press scroll down To Change the End Time Select the End Time entry field and press Set the End Time and press 53895_00048010161_E indb 16...

Page 175: ...sulin Units and press Set the number of Insulin Units and press Select the entry field for the amount of Carbs and press Set the amount of Carbs covered by the number of Insulin Units and press To Cha...

Page 176: ...nother Time Block Continue in order to add or remove Time Blocks otherwise press and proceed to Step 8 To Add a Time Block Select the last time block and press Select the End Time entry field and pres...

Page 177: ...you want to remove and press Select the End Time entry field and press Set the End Time to match the start time of the Time Block and press To save the changes and return to the Time Blocks screen pr...

Page 178: ...y field and press Set the Meal Rise limit and press To Change the Snack Size Select the Snack Size entry field and press Set the Snack Size amount and press To Change the Acting Time Select the Acting...

Page 179: ...173 5 11 10 To return to the Settings screen press Press 53895_00048010161_E indb 173 9 4 15 9 34 AM...

Page 180: ...meal with the expected meal rise In this case in contrast to regular meals an increase in your blood glucose result is not tolerated since the meal rise factor is not triggered for bolus advice calcu...

Page 181: ...nt percentages Changing advice options meal rise snack size acting time offset time Before continuing it is recommended that you review the Getting Started Guide determine how many time blocks you nee...

Page 182: ...s Bolus Advice is Set Up Main Menu Settings Bolus Advice Time Blocks 1 2 From the Main Menu select Settings and press 3 Select Bolus Advice and press Select Time Blocks and press 53895_00048010161_E i...

Page 183: ...elect the Time Block you want to remove and press To Add or Remove Time Blocks If you do not need to add or remove time blocks then proceed to To Change the Time Blocks To Add a Time Block Select the...

Page 184: ...and press Set the value and press To Change the Carb Ratio Select the entry field for the number of Insulin Units and press Set the number of Insulin Units and press Select the entry field for the amo...

Page 185: ...he Insulin Sensitivity level and press Press 6 To change another time block select the time block and press Return to Step 5 To return to the Bolus Advice screen press 53895_00048010161_E indb 179 9 4...

Page 186: ...Bolus Advice is Set Up Main Menu Settings Bolus Advice Health Events 1 2 From the Main Menu select Settings and press 3 Select Bolus Advice and press Select Health Events and press 53895_00048010161_...

Page 187: ...ntry field of the Health Event to be changed and press Set the percentage and press Repeat the previous steps to change other Health Events To save the changes and return to the Bolus Advice screen pr...

Page 188: ...ions Bolus Advice is Set Up Main Menu Settings Bolus Advice Advice Options 1 2 From the Main Menu select Settings and press Select Bolus Advice and press Select Advice Options and press 53895_00048010...

Page 189: ...g Time entry field and press Set the Acting Time duration and press To Change the Offset Time Select the Offset Time entry field and press Set the Offset Time duration and press To save the changes pr...

Page 190: ...ve Hyper Warning Limit message Consider checking for ketones bG and insulin regularly If your test result is below the hypo warning limit the meter displays the Below Hypo Warning Limit message Eat fa...

Page 191: ...185 5 Main Menu Settings Meter Warning Limits 1 2 From the Main Menu select Settings and press Select Meter and press 3 Select Warning Limits and press 53895_00048010161_E indb 185 9 4 15 9 34 AM...

Page 192: ...s Set the Hyper upper blood glucose level and press To Change the Hypo Blood Glucose Level Select the Hypo entry field and press Set the Hypo lower blood glucose level and press To save the changes an...

Page 193: ...The key lock feature allows you to lock all of the buttons on the meter except for the power on off button This serves as a safety measure against unintentional activation of meter functions 53895_00...

Page 194: ...188 Main Menu Settings Meter Key Lock 1 2 From the Main Menu select Settings and press Select Meter and press 3 Select Key Lock and press 53895_00048010161_E indb 188 9 4 15 9 34 AM...

Page 195: ...cked for the current session When the meter is turned on again the buttons are locked Key Lock Important Information When the buttons are locked you can still turn the meter on and off You can also ad...

Page 196: ...190 5 9 Setting the Language You can select a language from the predefined list 53895_00048010161_E indb 190 9 4 15 9 34 AM...

Page 197: ...191 5 Main Menu Settings Meter Language 1 2 From the Main Menu select Settings and press Select Meter and press 3 Select Language and press 53895_00048010161_E indb 191 9 4 15 9 34 AM...

Page 198: ...192 4 Press to display the Language options Select the desired Language and press To save the change and return to the Meter Menu screen press 53895_00048010161_E indb 192 9 4 15 9 34 AM...

Page 199: ...Carbs You can set up the meter for a specific carbohydrates Carbs unit Grams BE KE or CC Once the Carbs unit is set and bolus advice is activated the Carbs unit cannot be changed 53895_00048010161_E...

Page 200: ...194 Main Menu Settings Meter Units 1 2 From the Main Menu select Settings and press Select Meter and press 3 Select Units and press 53895_00048010161_E indb 194 9 4 15 9 34 AM...

Page 201: ...Once the Carbs unit Grams BE KE or CC is set and bolus advice is activated the Carbs unit cannot be changed If you need to change the Carbs unit contact the Accu Chek Customer Care Service Center at 1...

Page 202: ...luetooth Wireless Technology On or Off Main Menu Settings Meter Bluetooth 1 2 From the Main Menu select Settings and press Select Meter and press 3 Select Bluetooth and press 53895_00048010161_E indb...

Page 203: ...oth wireless technology either On or Off press and hold until the Bluetooth wireless technology icon changes Release To save the change and return to the Meter Menu screen press 53895_00048010161_E in...

Page 204: ...198 5 12 Pairing the Meter and Pump For complete pairing instructions see the Advanced Owner s Booklet 53895_00048010161_E indb 198 9 4 15 9 34 AM...

Page 205: ...me a button is pressed Even when the beeper is turned off the meter still beeps when an error message occurs When in the low battery condition the meter uses the medium beeper level if the beeper leve...

Page 206: ...Main Menu select Settings and press Select Sound Vibrate and press 3 To Change the Beeper Sound Level Select the Beeper entry field and press Select the Beeper sound level Off Low Medium or High and...

Page 207: ...ess Select the Vibrate mode On or Off and press To Change the Key Sound Select the Key Sound entry field and press Select the Key Sound mode On or Off and press To save the changes and return to the S...

Page 208: ...act the Trend Graph and the Trend Table see Reporting Your Data Trends in Section 4 4 Reporting Your Data For 12 hour time format time is displayed as HH MM A P example 3 53 pm and for 24 hour time fo...

Page 209: ...2 From the Main Menu select Settings and press Select Time Date and press 3 To Change the Time Format Select the Time Format entry field and press Select 12 hr or 24 hr Time Format and press 53895_00...

Page 210: ...s and press If Time Format is 12 hour select am or pm and press To Change the Date Select the Date entry field and press Set the Day and press Set the Month and press Set the Year and press To save th...

Page 211: ...sted that you review the Getting Started Guide before continuing Prior to setting up time blocks it is recommended that you determine how many time blocks you need and also determine the start end tim...

Page 212: ...oes not appear if bolus advice has been set up Select Time Blocks and press Change End Time Target Range Lower Value and or Target Range Upper Value Main Menu Settings Time Blocks 3 Select the time bl...

Page 213: ...value of the Target Range and press Set the value and press Select the entry field for the upper value of the Target Range and press Set the value and press To save the changes and return to the Time...

Page 214: ...hen you set the end time the meter sets this end time as the start time for the next time block The end time can be set in 30 minute increments To cancel changes press 53895_00048010161_E indb 208 9 4...

Page 215: ...ettings and press Time Blocks does not appear if bolus advice has been set up Select Time Blocks and press Add a Time Block Main Menu Settings Time Blocks 3 Select the last time block and press 53895_...

Page 216: ...be the start time of the added time block To save the changes and return to the Time Blocks screen press 5 Update the End Times and Target Ranges for all time blocks as needed See Change End Time Targ...

Page 217: ...nd press Time Blocks does not appear if bolus advice has been set up Select Time Blocks and press Remove a Time Block Main Menu Settings Time Blocks 3 Select the Time Block you want to remove and pres...

Page 218: ...e Block and press To save the changes and return to the Time Blocks screen press 5 Update the End Times and Target Ranges for the remaining time blocks as needed See Change End Time Target Range Lower...

Page 219: ...lay under different lighting conditions You can adjust the backlight level by pressing the backlight button on the front of the meter The backlight adjusts from low to medium to high and back to low a...

Page 220: ...ht setting when you press a button insert a test strip or when the meter displays the bG Results screen When in the low battery condition the meter uses the medium backlight level if the backlight lev...

Page 221: ...Warnings and Errors 6 1 Overview 216 6 2 List of Icons 217 6 3 Confirming a Reminder Warning or Error 219 6 4 List of Reminders 220 6 5 List of Warnings 228 6 6 List of Errors 234 53895_00048010161_E...

Page 222: ...pter provides you with detailed listings of all the icons reminders warnings and errors included in the meter i NOTE Blood glucose and bG are interchangeable and mean the same thing 53895_00048010161_...

Page 223: ...er Blood Glucose Averages Blood Glucose Test Bluetooth Wireless Technology Enabled Bolus Advice Bolus Advice Settings Carbs Icon Name Icon Control Test Date Download Data Transfer Error Extended Bolus...

Page 224: ...y Data Pen Syringe Bolus Pump Reminder Reminder Settings Reports Settings Icon Name Icon Sound Vibrate Settings Standard Bolus Not Confirmed Standard Bolus Confirmed Time Time Block Settings Time Chan...

Page 225: ...gs press Some error messages require a different confirmation such as Retest with new Strip or Replace batteries now To place some reminders in the snooze mode press See the following sections for mor...

Page 226: ...Reminder Title 4 Reminder Message 5 Dismiss i NOTE The meter beeps when it displays any reminder if the beeper setting is on The meter vibrates when it displays any of the following reminders if the...

Page 227: ...test Snooze Dismiss 15 minutes Dr Visit Today If the Dr Visit time has been set You have a Dr Appointment today at Settings Dr Visit Time 1 Or if the Dr Visit time has not been set You have a Dr Appo...

Page 228: ...lab test time has not been set You have a Lab Test today Dismiss Lab Test Tomorrow If the lab test time has been set You have a Lab Test tomorrow at Settings Lab Test Time 1 Or if the lab test time ha...

Page 229: ...ng occur when the particular reminder is enabled and scheduled Dr Visit Today Dr Visit Tomorrow Lab Test Today and Lab Test Tomorrow Reminders Displayed when you turn on the meter and a test strip has...

Page 230: ...cheduled and no blood glucose test was performed the reminder is displayed when the meter powers down When the meter displays the reminder and you do not press any meter buttons within 30 seconds the...

Page 231: ...s scheduled and no blood glucose test was performed the reminder is displayed when the meter powers down When the meter displays the reminder and you do not press any meter buttons within 30 seconds t...

Page 232: ...me the meter turns on and displays the reminder if a test strip has not been inserted If the meter is already on when the reminder is scheduled and no blood glucose test was performed the reminder is...

Page 233: ...r is scheduled and no blood glucose test was performed the reminder is displayed when the meter powers down Dismiss all active bG Test reminders by pressing Snooze the reminder for 15 minutes either b...

Page 234: ...xample 1 Warning Icon 2 No Only shown on a few warning screens 3 Warning Title 4 Warning Message 5 Yes or OK i NOTE The meter beeps when it displays a warning if the beeper setting is on 1 2 3 4 5 538...

Page 235: ...bs 1 Retest bG OK Bolus Advice Bolus Advice data deleted OK Bolus Advice Not Setup Advice not provided unless setup through Bolus Advice in Settings OK Bolus Advice Timeout Bolus Advice no longer poss...

Page 236: ...K Communication Lost See Pump OK Communication Warning Pump data not available Active Insulin may not be accurate OK Communication Warning Pump data not available recent Bolus data may not be accurate...

Page 237: ...ast communication with Pump OK Insulin Sensitivity Insulin Sensitivity seems unusual Check entries OK Invalid Active Insulin Unable to calculate the Active Insulin Bolus Advice not available OK Invali...

Page 238: ...ed conflicts with Hyper and or Hypo Warning Limit settings OK LO bG Warning Retest bG Contact your doctor OK Meter and Pump Not Paired Pair with Pump to use this feature OK Meter Battery Low Replace s...

Page 239: ...isplays a recommended amount of fast carbohydrates 2 On the meter display the activation chip is referred to as a code key Code key and activation chip are interchangeable and mean the same thing If y...

Page 240: ...ple 1 Error Icon 2 Menu This option is not available for all errors 3 Error Title 4 Error Message i NOTE The meter beeps when it displays an error even if the beeper setting is turned off 1 2 3 4 5389...

Page 241: ...Menu2 OK3 E 53 Bad Test Error Retest with new Strip E 54 Not Enough Sample Retest with new Strip E 55 Code Key Expired Turn Meter off replace Code Key and Strips1 Menu2 OK3 E 56 Sample Applied Early...

Page 242: ...Code key and activation chip are interchangeable and mean the same thing If you need an activation chip please contact Roche 2 Menu is only displayed when the meter is in a bG test screen 3 OK is onl...

Page 243: ...237 7Care and Maintenance 7 1 Overview 238 7 2 Changing the Batteries 239 7 3 Power Saving Tips 242 7 4 Cleaning the Meter 243 7 5 Maintenance and Testing 244 53895_00048010161_E indb 237 9 4 15 9 34...

Page 244: ...s important to properly care for and maintain your meter If you have any questions about the care and maintenance of your meter contact Accu Chek Customer Care at 1 800 688 4578 53895_00048010161_E in...

Page 245: ...ng the tab in the direction of the arrow and pulling up the door Remove the old batteries from the meter Insert three AAA batteries with the and ends matching the marks in the battery compartment 3 Pu...

Page 246: ...ased batteries should not be mixed with partially exhausted ones Batteries of different electrochemical systems grades or brands should not be mixed Failure to observe these precautions may result in...

Page 247: ...and replace the batteries Rechargeable batteries may be used in the meter However rechargeable batteries may not maintain the same battery life as non rechargeable batteries When the Low Battery warni...

Page 248: ...nserve battery life Use the low beeper setting Only turn on the vibrate feature when it is needed Turn off the meter when you are finished rather than utilizing the auto power off feature 53895_000480...

Page 249: ...lcohol Mild dishwashing liquid mixed with water 10 household bleach solution 1 part bleach plus 9 parts water made the same day Squeeze out any excess liquid from the cloth before you wipe the meter s...

Page 250: ...accurate results ensure your test strips and control solution have not expired and then perform a control test Perform a control test with each new vial of test strips To test the meter display turn o...

Page 251: ...245 8 8Troubleshooting 8 1 Overview 246 8 2 Troubleshooting the Accu Chek Aviva Combo Meter 247 53895_00048010161_E indb 245 9 4 15 9 34 AM...

Page 252: ...are at 1 800 688 4578 w WARNING Never make treatment decisions based on a warning or error message If you have any concerns contact Accu Chek Customer Care at 1 800 688 4578 i NOTE If you drop the met...

Page 253: ...Do not artificially heat or cool the meter Bluetooth icon flashing Communication ended due to a button press on the pump Check the pump and continue operation of the pump manually Ensure the pump has...

Page 254: ...grity cannot be confirmed Wait 8 hours for accurate bolus advice IMPORTANT Insulin doses and meals taken before the Bolus Advice warning are no longer reflected in the bolus advice calculation The met...

Page 255: ...p out of Stop mode The pump is currently delivering a bolus Allow the current bolus delivery to complete before delivering the next bolus Bolus Too High The bolus is above the allowed amount The bolus...

Page 256: ...ut of range of the meter Bolus delivery continuing see pump screen Ensure the meter and pump have Bluetooth wireless technology turned on Ensure the meter and pump are within communication range If th...

Page 257: ...munication range If the low battery icon is displayed on the meter the meter cannot communicate with the pump Replace the batteries Connection Lost The connection was lost between the meter and the pu...

Page 258: ...ble for this result Review data that was saved in My Data Then decide to modify data add data or begin a new bolus advice session E 51 Bad Strip Error The test strip is damaged The test strip is not p...

Page 259: ...2 Testing Your Blood Glucose If this still does not match the way you feel run a control test with your control solution and a new test strip If the control result is within the acceptable range revi...

Page 260: ...ivation chip Make sure the time and date in the meter are correct If you need a black activation chip please contact Accu Chek Customer Care at 1 800 688 4578 E 56 Sample Applied Early Blood or contro...

Page 261: ...r The time and date settings may be incorrect You have changed the batteries Ensure the time and date are correct and adjust if necessary See Chapter 5 Changing Meter Settings HI bG Warning Your blood...

Page 262: ...eless technology communication between the meter and pump regularly if you utilize bolus advice Insulin Sensitivity Insulin sensitivity is outside of the acceptable meter range Check your entries and...

Page 263: ...valid Hypo Values The hypo warning limit value must be less than all of your target ranges in the time block settings Reset the hypo warning limit or revise the target ranges in time blocks and re ent...

Page 264: ...nging Meter Settings LO bG Warning Your blood glucose may be lower than the measuring range of the system Treat your low blood glucose as recommended by your healthcare professional If you are experie...

Page 265: ...pump was unsuccessful Restart the pairing process See the Advanced Owner s Booklet Pump Not Available The pump is out of the communication range of the meter Ensure the meter and pump have Bluetooth w...

Page 266: ...ck activation chip please contact Accu Chek Customer Care at 1 800 688 4578 Ensure the time and date are correct If the time or date are not correct change the time and date on the pump See Chapter 5...

Page 267: ...261 8 If you have a question or if you see any other error screen please contact Accu Chek Customer Care at 1 800 688 4578 53895_00048010161_E indb 261 9 4 15 9 34 AM...

Page 268: ...262 53895_00048010161_E indb 262 9 4 15 9 34 AM...

Page 269: ...ions 265 9 3 Specifications 266 9 4 Product Safety Information 268 9 5 Disposing of the Meter Strips Lancets and Batteries 271 9 6 Warranty 272 9 7 Additional Supplies 274 9 8 Information for Healthca...

Page 270: ...264 9 1 Overview This chapter provides you with important performance information regarding the meter 53895_00048010161_E indb 264 9 4 15 9 34 AM...

Page 271: ...265 9 2 Product Limitations Please read the literature packaged with your test strips to find the latest information on product specifications and limitations 53895_00048010161_E indb 265 9 4 15 9 34...

Page 272: ...trip package insert Test strip storage conditions Refer to the test strip package insert Meter storage conditions with batteries inserted 20 C to 50 C System operating conditions Refer to the test str...

Page 273: ...h batteries inserted Construction Hand held Protection class III Meter type The Accu Chek Aviva Combo Meter is suitable for continuous operation Control solution storage conditions 2 C to 32 C Interfa...

Page 274: ...frequency RF technology that operates in the unlicensed industrial scientific and medical band at 2 4 to 2 485 GHz The RF channel utilized for communication between the meter and the pump is not an o...

Page 275: ...it is recommended that you increase distance between meter and that device You may also turn off the interfering device In addition you may turn off Bluetooth wireless technology on the meter and del...

Page 276: ...son accuracy venous blood repeatability and control solution reproducibility The system is calibrated with venous blood containing various levels of glucose The reference values are obtained using the...

Page 277: ...or contaminated products Contact your local health department or other appropriate authorities for proper handling and disposal of used meters used test strips used lancets and used batteries Consider...

Page 278: ...Diagnostics Canada will replace it with a new Accu Chek Aviva Combo Meter or equivalent product free of charge The warranty on the replacement meter will expire on the date of the original warranty e...

Page 279: ...OR A PARTICULAR PURPOSE IF ANY IS IMPLIED FROM THE SALE OF THE METER SHALL EXTEND FOR A LONGER DURATION THAN FIVE YEARS FROM THE DATE OF PURCHASE Warranty Instructions All requests for return of Accu...

Page 280: ...sories are available from your authorized Roche Diabetes Healthcare Center pharmacies or your medical surgical supply dealer Test Strips Accu Chek Aviva Test Strips Control Solutions Accu Chek Aviva C...

Page 281: ...als Follow the infection control procedures appropriate for your facility A drop of fresh whole blood is required to perform a blood glucose test Refer to the test strip package insert for additional...

Page 282: ...276 53895_00048010161_E indb 276 9 4 15 9 34 AM...

Page 283: ...Equivalent equal to 12 grams of carbohydrates bG Blood Glucose C Degrees Celsius or Centigrade Carbs Carbohydrates CC Carbohydrate Choice equal to 15 grams of carbohydrates FCC Federal Communications...

Page 284: ...zation KE Kohlenhydrateinheit equal to 10 grams of carbohydrates LCD Liquid Crystal Display mmol L Millimoles per Liter N A Not Applicable NIST National Institute of Standards and Technology United St...

Page 285: ...279 Abbreviation Definition RF Radio Frequency SD Standard Deviation U Units bolus insulin units 53895_00048010161_E indb 279 9 4 15 9 34 AM...

Page 286: ...asure are available on the meter Abbreviation Unit of Measurement Gram Equivalent g Grams 1 gram KE Kohlenhydrateinheit 10 grams BE Bread Equivalent 12 grams CC Carbohydrate Choice 15 grams Standard u...

Page 287: ...ety related notes in the instructions for use accompanying this product A NOTE is used to provide additional information Temperature limitation store at Manufacturer Catalogue number In vitro diagnost...

Page 288: ...d High mmol L 6 5 19 5 0 1 Hyper Warning Limit bG Threshold Low mmol L 3 5 5 0 1 Hypo Warning Limit Carb Ratio carbs grams BE KE CC 1 0 1 0 1 0 1 240 20 24 16 1 0 1 0 1 0 1 No entry g No entry BE No e...

Page 289: ...its 0 501 0 1 N A Hyper Warning Limit mmol L 10 19 5 0 1 16 5 Hypo Warning Limit mmol L 3 5 0 1 4 Illness health event 50 50 1 0 Insulin Sensitivity bG mmol L 0 1 55 4 0 1 No entry mmol L Insulin Sens...

Page 290: ...24 2 2 4 1 6 1 0 1 0 1 0 1 No entry g No entry BE No entry KE No entry CC Standard Bolus insulin Units 0 50 0 1 N A Stress health event 50 50 1 0 Target Range Upper Value mmol L 5 5 15 0 1 8 Target Ra...

Page 291: ...ders To turn on a bG test reminder see Setting Alarm Clock Reminders bG Test Other in Chapter 5 Changing Meter Settings Test Reminder Default Time of Day 1 7 00 2 9 00 3 11 00 4 12 00 5 14 00 6 16 00...

Page 292: ...hcare professional about setting up time blocks to help you manage your diabetes To adjust the time blocks see Chapter 5 Changing Meter Settings Time Block 24 Hour Format 1 0 00 5 30 2 5 30 11 00 3 11...

Page 293: ...that influence bolus advice calculations including meal rise snack size acting time and offset time After High bG Reminder A reminder to retest your blood glucose When enabled this reminder occurs aft...

Page 294: ...inder Blood Glucose bG The level of sugar in the blood Bluetooth Wireless Technology Wireless short range communications technology which connects devices such as meter and pump in order to exchange i...

Page 295: ...y or rapidly Carbohydrates are generally counted to calculate a bolus insulin dose Control Result Value displayed on meter as the result of a control test When the Control Result is within the range s...

Page 296: ...meter and pump are communicating Health Events A pop up menu selection Exercise 1 Exercise 2 Stress Illness Premenstrual or Fasting that allows information to be stored with a blood glucose result or...

Page 297: ...t enough insulin to help your body use glucose for energy Without enough insulin glucose builds up in the blood Key Lock A meter function which disables the keys buttons in order to prevent its uninte...

Page 298: ...meter and pump are communicating Note Additional information Offset Time Offset time takes into account the expected delay for the blood glucose level to actually fall during the acting time of insul...

Page 299: ...Two keys under the meter display used to navigate through the user interface Just above each soft key the meter display shows the selection e g Save Cancel Back etc Standard Bolus A bolus that is imme...

Page 300: ...Up to eight time periods within one day to facilitate your changing insulin needs throughout the day Time Range The user sets the duration of time There is a start and end time User A person using th...

Page 301: ...6 156 227 B backlight 26 27 213 backlight button 17 23 batteries 19 batteries changing 239 batteries low 38 batteries type 239 BE 193 beeper setting 199 bG threshold 152 blood glucose averages 106 blo...

Page 302: ...modifying 92 data reporting 104 data trends 108 data viewing 42 date reminders 36 160 date setting 202 display 17 25 247 disposing meter 271 dr visit reminder 160 221 223 E electromagnetic compatibil...

Page 303: ...87 key sound setting 199 L lab test reminder 222 lancing device 52 53 language 190 low bG retest reminder 222 M maintenance meter 244 meal rise 172 174 183 meal time 56 58 96 meter 7 17 meter summary...

Page 304: ...ation 104 standard week reporting 129 supplies 274 symbols explanation 281 symptoms hyperglycemia hypoglycemia 68 T table standard day 125 table standard week 134 table target 141 table trend 116 targ...

Page 305: ...299 V vibrate setting 199 W warnings list of 229 warranty 272 53895_00048010161_E indb 299 9 4 15 9 34 AM...

Page 306: ...300 53895_00048010161_E indb 300 9 4 15 9 34 AM...