7-68
Dialer: Parameter
Quick-Key Parameter
Default
Range
55
77
88
Swinger Limit
00
00 to 15
The Alarm Limit option is provided to prevent multiple triggering on a zone within
the activated time. Setting 01: A triggered zone is not transmitted again if this has
already happened. If you raise the limit, the alarm is transmitted according to your
setting.
NOTE:
Enter 00 to disable the alarm abort. Every time the zone triggers, the alarm is transmitted
again.
55
77
99
Periodic Test
Defines a time in which the
ABUS wireless alarm system
calls the UD numbers
to test the telephone connection. This feature is possible only if a PC with active
software is ready to receive.
55
77
99
22
UD Test
Hr:00
Min:00
00-24 hours
00-59 minutes
Under this option, enter the following: The time for the periodic test call (in 24-hour
format) and the frequency interval.
To program the test time and the intervals for periodic transmissions:
1. Press
22
. You see the following on the display:
2. Enter the time in 24-hour format.
3. Define the frequency interval (D) according to the table below. The first test call
starts on the day of programming.
D Meaning
0
Never
H
Hourly
M
Monthly
1
Daily
2
Every second day
3
Every third day
4
Every fourth day
5
Every fifth day
6
Every sixth day
7
Every seventh day
4. Press
to exit the menu option.
55
77
00
More
This menu determines when the system should transmit the reset message. You can select
between three possibilities:
11
on BTO (bell time out) ,
22
follow zone,
33
at disarm