03
03
Exit(OP)/Entry
Default for zone 1
Armed/internal
Zone type
Exit(OP)/Entry
behaves like zone type
Exit/Entry 1
except that the zone does
not have to be closed at the moment of activation. However, the zone must be closed
before the exit delay time expires, or otherwise there is an alarm. This zone type is usually
assigned to opening contacts on front and side doors.
22
22
44
ZZ
ZZ
+
04
04
Entry follower
Armed/internal
Zone type
Entry follower
does not trigger an alarm if an entry delay time is started first. If
no entry delay is active, this zone triggers an alarm immediately if the area is activated. This
zone type is usually assigned to motion sensors that monitor the entrance area, in addition
to opening contacts on the entrance doors.
22
22
44
ZZ
ZZ
+
05
05
Instant
Armed/internal
If the area is active, the
Instant
zone type triggers an alarm immediately when the zone is
opened. This zone must not be opened during the entry and exit delay period. This is the
usual zone type for motion and opening sensors that are not in the entrance area.
22
22
44
ZZ
ZZ
+
06
06
I+Exit/Entry 1
(In Exit/Entry 1)
Default for zone 2
Armed
The
I+Exit/Entry 1
zone type is similar to zone type
Exit/Entry 1
. However, this zone type
is
not
monitored for an internally activated system.
IMPORTANT INFORMATION:
To shorten the exit delay time, press
twice. This sets the entry delay time to 0. If
this zone is now opened, there is an immediate alarm.
22
22
44
ZZ
ZZ
+
07
07
I+Exit/Entry 2
IExit/Entry 2)
Armed
See above. However, for zones of this type, the times of
Group 2
apply.
22
22
44
ZZ
ZZ
+
08
08
I+Exit(OP)/Entry
(IExit(OP)/Entry)
Armed
The
I+Exit(OP)/Entry
zone type is similar to zone type
Exit(OP)/Entry
. However, this zone
type is
not
monitored for an internally activated system.
22
22
44
ZZ
ZZ
+
09
09
I+Entry follow
(IEntry Follower)
Armed
The
I+Entry follow
zone type is similar to zone type
Entry Follower
. However, this zone
type is
not
monitored for an internally activated system.