7-35
7.2.6
11
66
Tamper Sound
In the
Tamper Sound
menu, you can define the sounds generated by the
ABUS wireless alarm system
following a tamper in a zone,
the ABUS wireless alarm centre housing, the wireless operating panel, or any other device. You can also adjust the sounder volume
for alarms and their acknowledgement.
To access the Tamper Sound menu:
1.
Select the
System
menu as described on page 7-23.
2.
In the
System
menu, press
66
to access the menu option of the
Tamper Sound
menu. You see the
following on the display:
3.
Select and configure the settings in the
Tamper Sound
menu as follows:
Tamper Sound:
Quick-Key Parameter
Default
Range
11
66
11
Tamper sound
Bell/A Buzzer/D
1 to 5
Programs the signals generated by a tamper alarm.
Setting
Sound
1
Silent
2
Bell only (external sounder)
3
Buzzer only (piezo on operating panel)
4
Bell and buzzer
5
Bell/Arm, Buzzer/Disarm
NOTE:
If you set sounder/active and buzzer/inactive, the system will activate only the buzzer when
in deactivated state. If the system is active, the external sounder is also activated.
11
66
22
Speaker Volume
Adjusts the volume of the integrated sounder in the event of an alarm and for
acknowledgement.
11
66
22
11
Alarm
5
0 to 5
If you confirm this menu option, the sounder is activated briefly at the volume defined.
You can adjust the volume with buttons 0 to 5.
The setting 0 deactivates the sounder, and 5 is the loudest setting.
11
66
22
22
Squawk
5
0 to 5
If you confirm this menu option, the sounder is activated briefly at the volume defined.
You can adjust the volume with buttons 0 to 5.
The setting 0 deactivates the sounder, and 5 is the loudest setting.