Exit Termination
A zone with the
Exit Termination
zone type behaves like a zone with the
Exit(OP)/Entry
zone type. However, the difference is that an exit delay time is ended immediately if this
zone is opened or closed during the exit delay time.
When you enter the protected area, the entry delay time of Group 1 starts as usual.
22
22
44
ZZ
ZZ
+
19
19
Latch Keyswitch
A zone with the
Latch Keyswitch
zone type is used for activating/deactivating one or
more areas. The area remains active as long as the zone is open, and is deactivated
as soon as the zone is closed.
22
22
44
ZZ
ZZ
+
20
20
Entry Fo Stay (Internal)
If armed, this zone works like a zone type Entry Follower. If stay armed this zone type
works like an exit/entry zone of Group 1.
22
22
44
ZZ
ZZ
+
21
21
Keyswitch Delay
A zone with the
Keyswitch Delay
zone type is used for activating/deactivating
one or more areas. This zone type is comparable to zone type
Key switch
,
except that the area is first activated following expiry of the entry/exit delay
time of Group 1.
22
22
44
ZZ
ZZ
+
22
22
Latch KSW Delay
A zone with the
Latch KSW Delay
zone type is used for
activating/deactivating one or more areas. The area remains active as long as
the zone is open, and is deactivated as soon as the zone is closed. This zone
type is comparable to zone type Blockschloss, except that the area is first
activated following expiry of the entry/exit delay time of Group 1.
22
22
44
ZZ
ZZ
+
10
10
I+Instant
(IInstant)
Armed
The
I+Instant
zone type is similar to zone type
Instant.
However, this zone type is
not
monitored for an internally activated system.
22
22
44
ZZ
ZZ
+
11
11
UO Trigger
Armed
The
UO Trigger
zone type controls a switch output whether the system is active or inactive.
For example: for temperature sensors that control a ventilator.
22
22
44
ZZ
ZZ
+
12
12
Day Zone
Armed
A zone with the
Day Zone
zone type immediately triggers an alarm in an internally or
externally activated system. If the system is inactive, a fault is displayed on the alarm
system display. The fault message can now control a switch output or be viewed by the
user in the user menu under
Troubles
. This zone type is mostly used to protect emergency
exits.
22
22
44
ZZ
ZZ
+
13
13
24 Hours
Default for zone 3
All
A zone with the 24 Hours zone type triggers an alarm immediately, irrespective of the
state of the alarm system. This zone type is mostly used for passive glass breakage
sensors.
22
22
44
ZZ
ZZ
+
14
14
Fire
Default for zone 3
All
A zone with the
Fire
zone type triggers a fire alarm immediately, irrespective of the state of
the alarm system. This zone type is used for smoke detectors.
NOTE:
Zone 33 cannot be programmed as a fire zone.
22
22
44
ZZ
ZZ
+
15
15
Panic
All
A zone with the
Panic
zone type triggers a panic alarm immediately, irrespective of
the state of the alarm system. This zone type is not intended for panic messages
triggered by remote control. See the
key-fob
menu.
22
22
44
ZZ
ZZ
+
16
16
Special
All
A zone with the
Special
zone type triggers a medical emergency alarm (not a panic
alarm) immediately, irrespective of the state of the alarm system.
22
22
44
ZZ
ZZ
+
17
17
Pulse Keyswitch
A zone with the
Pulse Keyswitch
zone type can be used to activate/deactivate an
area. The state change must be in the form: closed – open (pulse) – closed.