USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
TERMINAL BLOCK SETTINGS
Each terminal block is linked to a parameter: they can all be identified with letter
E
.
E0
INPUTS, NEGATIVE-POSITIVE COMMON
2
NEGATIVE
E1
TERMINAL BLOCK 9 - E1
Go
START
E2
TERMINAL BLOCK 10 - E2
PE
PEDESTRIAN
E3
TERMINAL BLOCK 11 - E3
N
AUTO-ENABLE
E4
TERMINAL BLOCK 12 - E4
N
AUTO-ENABLE
E5
TERMINAL BLOCK 22 - E5
N
AUTO-ENABLE
E6
TERMINAL BLOCK 23 - E6
N
AUTO-ENABLE
E7
TERMINAL BLOCK 24 - E7
N
AUTO-ENABLE
E8
TERMINAL BLOCK 25 - E8
N
AUTO-ENABLE
E9
TERMINAL BLOCK 26 - E9
N
AUTO-ENABLE
E0
INPUTS, NEGATIVE-POSITIVE COMMON
E’ possibile riferire gli ingressi della morsettiera sia al POSITIVO che al NEGATIVO.
Per selezionare il comune degli ingressi al NEGATIVO ( morsetti 14, 15, 16 etichettati con -) impostare
E0
=
2
.
Per selezionare il comune degli ingressi al POSTIVO (morsetti 17, 18 etichettati con +) impostare
E0
=
1
.
E1
TERMINAL BLOCK 9 - E1 - NORMALLY OPEN
Terminal block 9 is associated with a normally open (N.O.) contact. The parameters that can be set are:
N
DISABLED,
GO
START,
PE
PEDESTRIAN,
PO
OPEN DEAD MAN,
PC
CLOSE DEAD MAN,
EL
ELECTRIC LOCK.
E2
TERMINAL BLOCK 10 - E2 - NORMALLY OPEN
Terminal block 10 is associated with a normally open (N.O.) contact. The parameters that can be set are:
N
DISABLED,
GO
START,
PE
PEDESTRIAN,
PO
OPEN DEAD MAN,
PC
CLOSE DEAD MAN,
EL
ELECTRIC LOCK.
E3
TERMINAL BLOCK 11 - E3 - NORMALLY CLOSED
Terminal block 11 is associated with a normally closed (N.C.) contact. The parameters that can be set are:
N
DISABLED,
St
STOP. This control unit is supplied with the standard setting where terminal block 11 is disabled (
E3
=
n
).
When a NORMALLY CLOSED contact is connected to terminal block 11, it is automatically detected by the control unit that sets
the parameter of the terminal block to the correct safety fuction, in this case
E3
=
St
STOP. This feature is called AUTO-ENABLE.
E4
TERMINAL BLOCK 12 - E4 - NORMALLY CLOSED
Terminal block 12 is associated with a normally closed (N.C.) contact. The parameters that can be set are:
N
DISABLED,
tc
CLOSING PHOTOCELL - MODE 1, and
td
CLOSING PHOTOCELL - MODE 2. This control unit is supplied with
the standard setting where terminal block 12 is disabled (
E4
=
n
). When a NORMALLY CLOSED contact is connected to terminal
block 12, it is automatically detected by the control unit that sets the parameter of the terminal block to the correct safety fuction,
in this case
E4
=
tc
CLOSING PHOTOCELL - MODE 1. This feature is called AUTO-ENABLE.
E5
TERMINAL BLOCK 13 - E5 - NORMALLY CLOSED
Terminal block 13 is associated with a normally closed (N.C.) contact. The parameters that can be set are:
N
DISABLED,
ta
OPENING PHOTOCELL,
tc
CLOSING PHOTOCELL - MODE 1. This control unit is supplied with the standard
setting where terminal block 13 is disabled (
E5
=
n
). When a NORMALLY CLOSED contact is connected to terminal block 13, it
is automatically detected by the control unit that sets the parameter of the terminal block to the correct safety fuction, in this case
E5
=
tA
OPENING PHOTOCELL. This feature is called AUTO-ENABLE.
E6
TERMINAL BLOCK 14 - E6 - NORMALLY CLOSED
Terminal block 14 is associated with a normally closed (N.C.) contact. The parameters that can be set are:
n
DISABLED,
Ao
LIMIT SWITCH OPENING MOTOR A. This control unit is supplied with the standard setting where terminal block
14 is disabled (
E6
=
n
). When a NORMALLY CLOSED contact is connected to terminal block 14, it is automatically detected by
the control unit that sets the parameter of the terminal block to the correct safety fuction, in this case
E6
=
Ao
LIMIT SWITCH
OPENING MOTOR A. This feature is called AUTO-ENABLE.