4
USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
230V CONNECTIONS - MOTORS AND FLASHING LAMPS
MOTOR
B
MOTOR
A
THE LIGHT IS OPEN
WHEN ONE OF THE
TWO MOTORS IS
MOVING
GENERAL
PE
N
L
GROUND
NEUTRAL
PHASE
MOTOR A (600 W - 230 VAC)
1
2
3
COMMON
OPEN
CLOSE
MOTOR B (600 W - 230 VAC)
4
5
6
COMMON
OPEN
CLOSE
LIGHT (60 W - 230 VAC)
7
8
COMMON
OPEN
PLUG IN FOR
RECEIVER
FUSE 5A
230 VAC
PLUG IN FOR
RECEIVER 2