14
15
USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
OPERATIONAL REPORTS AND PRIORITIES
pe
PEDESTRIAN
The PEDESTRIAN function can open and close door A of the gate
for the time
F1
programmed. Its operation also depends on the
programming of the parameters made (
F5
= step-by-step mode /
F6
= multiple residents mode - see “GENERAL FUNCTIONS”) and
on the status of the other inputs.
e1
9
e2
10
r3
op
OPEN
The OPEN function always starts the gate by opening depending
on the status of the photocells, stop and limit switches.
e1
9
e2
10
r6
r7
CL
CLOSE
The CLOSE function always starts the gate by closing depending
on the status of the photocells, stop and limit switches.
e1
9
e2
10
r6
r7
EL
ELECTRIC LOCK
The ELECTRIC LOCK function activates the electric lock
for 3 seconds. The parameter
L0
must be set to the following val-
ues
L0
=
00
or
L0
=
01
.
r6
r7
do
ACTIVATE OUTPUT
The ACTIVATE OUTPUT function starts the function connected to
the programmable outputs
o1
and
o2
. The output functions
must be connected to the correct source (see PROGRAMMABLE
OUTPUTS).
r6
r7
9p
AUTOMATIC
PROGRAMMING
ERROR
This error is reported after automatic programming of SENSOR
p6
. Error
9P
indicates that one or more parameters related to
the obstacle sensor have not been calibrated.
To check which parameters are not programmed, check the value
of the following parameters
p6
,
p7
,
b7
and
b8
(see “CONFIG-
URATION MOTOR A/B”). The parameters set to
n
have not been
programmed.
ab
LIMIT SWITCH MOTOR
A + LIMIT SWITCH
MOTOR B
The function LIMIT SWITCH MOTOR A when opening or closing is
active at the same time as the function LIMIT SWITCH MOTOR B
when opening or closing.
If the gate is fully closed and both closing limit switches (motor A
and motor B) are installed, the display will show
ab
subject to the
priority of other events.
e6
22
e8
24
e7
23
e9
25
ao
OPENING LIMIT
SWITCH MOTOR A
The function OPENING LIMIT SWITCH OF MOTOR A is active: it
ends the stroke of motor A when opening.
e6
22
ac
CLOSING LIMIT
SWITCH MOTOR A
The function CLOSING LIMIT SWITCH OF MOTOR A ends the
stroke of motor A when closing.
e7
23
o2
OPENING LIMIT
SWITCH MOTOR B
The function OPENING LIMIT SWITCH OF MOTOR B is active: it
ends the stroke of motor B when opening.
e8
24
oc
CLOSING LIMIT
SWITCH MOTOR B
The function CLOSING LIMIT SWITCH OF MOTOR B ends the
stroke of motor B when closing.
e9
25
--
STAND BY
No function is active, no event is detected