USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
GENERAL FUNCTIONS
f7
FAST CLOSURE
MINIMUM:
n
MAXIMUM:
y
The FAST CLOSURE function allows the gate to be closed after passing in front of both photocells (open and close or close and open).
Closing begins 5 seconds after passing in front of the photocells. This function is only enabled once per WORKING CYCLE and if the gate
movement is not interrupted.
If
F7
= all START orders initiate this function: the remote controls stored with the functions
r1
START,
r3
PEDESTRIAN,
r4
FAST
CLOSURE, the terminal board inputs associated with the START
go
, OPEN
oP
or PEDESTRIAN functions
pe
. If
F7
=
n
(disabled) only
remote controls stored with the radio function
r4
activate the FAST CLOSURE.
F8
PHOTOCELLS LOGIC: SLIDING
MINIMUM:
n
MAXIMUM:
y
If
F8
=
n
the photocells operate with the logic of SWING GATE automation:
- OPENING PHOTOCELLS (terminal 13 parameter
E5
=
tA
): suspend the OPENING as long as the beam is interrupted. Reverses the
movement status from CLOSING to OPENING SUSPENDED. During OPENING they have no effect on the ongoing operation.
- CLOSING PHOTOCELLS (terminal 12 parameter
E4
=
tc
,
E4
=
td
): reverse the movement from CLOSING to OPENING.
If
F8
=
y
the photocells operate with the logic of SLIDING automation:
- OPENING PHOTOCELLS (terminal 13 parameter
E5
=
tA
): during OPENING they reverse the movement for 3 seconds. After these 3
seconds, CLOSING is interrupted. A subsequent START order starts the gate in CLOSING mode.
They have no effect during the CLOSING operation.
- CLOSING PHOTOCELLS (terminal 12 parameter
E4
=
tc
,
E4
=
td
): reverse the movement from CLOSING to OPENING. They have
no effect during the OPENING operation.
L0
KICK BACK
MINIMUM:
0
MAXIMUM:
3
This parameter allows changes to be made to the operating logic of terminals 20 + e 21 - (
L0
) associated with the electric lock. This output
is useful for controlling a 12VDC electric lock or a 3 W 12 VDC LED flashing light. The output of the electric lock can also be controlled by
remote control.
L0
=
00
→
The output is disabled. Only remote controls associated with the function
EL
(activate the electric lock for 3 seconds) can
activate the control unit’s output 20 + e 21 - (
L0
). The activation of the electric lock by remote control can be useful to manage a pedestri-
an gate adjacent to the automatic gate.
L0
=
01
→
The output is enabled to manage an electric lock installed on the door moved by motor A. At the beginning of each
OPENING movement, the control unit releases the electric lock. Remote controls stored as
EL
unlock the electric lock.
L0
=
02
→
The output is enabled with an intermittent flashing function. During OPENING, the flashing light will perform fast flashes.
During CLOSING the flashes will be slow. During the automatic closing time, the flashing light is
permanently lit.
L0
=
03
→
The output is enabled with the steady light function during the operation. During OPENING, CLOSING and the AUTOMATIC
CLOSING TIME the flashing light is on.
L1
OIL RECYCLING / MOTOR HEATING
MINIMUM:
0
min
MAXIMUM:
8
min
With this function it is possible to heat the motors and the control unit box cyclically. In the case of systems with hydraulic motors, it is
useful to circulate the oil periodically: each cycle lasts 10 minutes and
L1
represents the minutes that the motor/box is heated in each
cycle. This function is activated after 10 minutes with the gate fully closed or open: any operation on the control unit or interruption of a
photocell resets the time count to zero. The motors are active in the final part of each cycle. For example, by setting
L1
=
03
the motors
remain switched off for 7 minutes and then switched on for the remaining
3
minutes after the function is active (i.e. after 17 minutes from
the last operation performed).
L3
ONLY MOTOR A MODE
MINIMUM:
0
MAXIMUM:
y
By enabling this function
L3
=
y
only motor A will be managed. The parameters relating to motor B (
b1
–
b8
) can no longer be mod-
ified. This function is useful when installing a 1 door swing gate or sliding gates. If this control unit is used on a sliding gate, set parameter
F8
=
y
to select the correct photocell logic.