26
USER MANUAL - 230 VAC MULTIFUNCTION CONTROL UNIT - 051D
PROGRAMMABLE OUTPUTS
ALL EXAMPLES ASSUME THAT THE PLUG-IN RELAY EXPANSION MODULE (APE 570/0022) HAS BEEN CONNECTED TO THE CONTROL
UNIT’S OUTPUT PINS.
EXAMPLE: remote control configuration for controlling a light
1. Store a remote control as
r6
.
2. Select the parameter
r6
again.
3. Press and hold down the (
-
) KEY on the control unit. The display starts flashing showing
r6
.
4. When the display shows
r6
without flashing, release the (
-
) KEY.
5. Using the (
+
)(
-
) KEYS, select the
do
function.
6. Using
(
←
) (
→
) KEYS
select the parameter
o1
/
o2
.
7. Using the (
+
)(
-
) KEYS, select the
05
function.
8. Exit the menu using the
(
←
) (
→
) KEYS
.
The remote control stored by performing this procedure will switch the output status without changing the gate status.
EXAMPLE: configure a remote control to signal a dead man opening movement
1. Store a remote control as
r6
.
2. Select the parameter
r6
again.
3. Press and hold down the (
-
) KEY on the control unit. The display starts flashing showing
r6
.
4. When the display shows
r6
without flashing, release the (
-
) KEY.
5. Using the (
+
)(
-
) KEYS, select the
Po
function.
6. Using
(
←
) (
→
) KEYS
select the parameter
o1
/
o2
.
7. Using the (
+
)(
-
) KEYS, select the
06
function.
8. Exit the menu using the
←
) (
→
) KEYS
.
When the remote control button, stored following the above procedure, is transmitting, the gate will move in the OPEN direction and
simultaneously the output will be activated.
EXAMPLE: configure a remote control to signal a dead man closing movement
1. Store a remote control as
r7
.
2. Select the parameter
r7
again.
3. Press and hold down the (
-
) KEY on the control unit. The display starts flashing showing
r7
.
4. When the display shows
r7
without flashing, release the (
-
) KEY.
5. Using the (
+
)(
-
) KEYS, select the
Pc
function.
6. Using
(
←
) (
→
) KEYS
select the parameter
o1
/
o2
.
7. Using the (
+
)(
-
) KEYS, select the
08
function.
8. Exit the menu using the
(
←
) (
→
) KEYS
When the remote control button, stored following the above procedure, is transmitting, the gate will move in the CLOSE direction and
simultaneously the output will be activated.
EXAMPLE: transforming a 230VAC light into a intermittent flashing light
1. Using
(
←
) (
→
) KEYS
select the parameter
o1
/
o2
.
2. Using the (
+
)(
-
) KEYS, select the
03
function.
3. Exit the menu using the
(
←
) (
→
) KEYS
The lamp will turn on and off quickly during opening, slowly during closing and will remain on during the AUTO-CLOSE TIME.